Manual 2385154100C 6/21
SERVICE
MANUAL
Troubleshooting Guide
and Instructions for Service
(To be performed ONLY by
qualified service providers)
Models Covered
by This Manual:
PDV Series Models:
RG2PDV40S*(N,X)
RG2PDV50S*(N,X)
RG2PDV50H*(N,X)
RG2PDV75H*(N,X)
LG2PDV50H60*(N,X)
LG2PDV75H80*(N,X)
(*) Denotes Warranty Years
Power Direct Vent Gas Water Heaters
PDV Series

Questions and Answers

  • R
    Ruben CollinsAug 13, 2025
    How to fix Bradford White Water Heater when the control LED is not on?
    • A
      Alyssa HayesAug 13, 2025
      If the control LED is not on or flashing on your Bradford White Water Heater, it could be due to the control power switch being in the “OFF” position or an interruption in the supply voltage. To resolve this, turn the power on.
  • D
    Dr. Sara UnderwoodAug 16, 2025
    What to do if my Bradford White RG2PDV40SN Water Heater flashes four times?
    • M
      michaelsharpAug 17, 2025
      If your Bradford White Water Heater shows four flashes with a three-second pause, it could be due to several reasons: the temperature sensor might be out of calibration, the gas control could be faulty, or there might be a plumbing leak. The suggested solution is to replace the gas control.
  • M
    Monica WoodAug 21, 2025
    What does it mean when my Bradford White RG2PDV40SN Water Heater flashes five times?
    • B
      Brandon SantiagoAug 21, 2025
      If your Bradford White Water Heater displays five flashes with a three-second pause, it indicates that the pilot valve is stuck in the open position. The suggested solution is to replace the gas control.
  • A
    Alexis NortonAug 25, 2025
    What does three flashes mean on a Bradford White RG2PDV40SN?
    • J
      Jason WilliamsAug 25, 2025
      If your Bradford White Water Heater shows three flashes with a three-second pause, possible causes include a vent blockage or improper vent configuration, kinked or blocked pressure switch tubing, a faulty pressure switch, the blower not spinning up to speed, the blower or exhaust temperature being too high, or a faulty blower temperature switch.
  • A
    Angela MelendezAug 28, 2025
    What causes a 'Six-two flash, three second pause' error on a Bradford White RG2PDV40SN?
    • B
      Brandi WalterAug 28, 2025
      If your Bradford White Water Heater is showing a 'Six-two flash, three second pause' error, the possible causes are: vent blockage or improper vent configuration; pressure switch tubing kinked or blocked; faulty pressure switch; vent termination being affected by wind; blower not spinning up to speed; blower temp or exhaust temp too high; or a faulty blower temperature switch. The suggested solution is to check the vent or vent tables.
  • J
    James RogersSep 1, 2025
    What does 'Six-three flash, three second pause' mean on my Bradford White Water Heater?
    • A
      Alex ReynoldsSep 1, 2025
      If your Bradford White Water Heater is showing a 'Six-three flash, three second pause' error, the possible causes are: unstable pilot; pilot tube blocked or restricted; oxidation build up on pilot electrode; wire damage to pilot assembly or bad connection at gas valve; insufficient combustion air; gas pressure is out of specification.
  • M
    michael69Sep 4, 2025
    What to do for 'Six-four flash, three second pause' on Bradford White RG2PDV40SN?
    • G
      Glenn CarterSep 4, 2025
      If your Bradford White Water Heater is showing a 'Six-four flash, three second pause' error, the pilot valve may be stuck in the open position. The suggested solution is to replace the gas control.
  • A
    Amy ScottSep 8, 2025
    Why is my Bradford White RG2PDV40SN showing 'Eight-two flash, three second pause'?
    • B
      Brian MartinSep 8, 2025
      If your Bradford White Water Heater is showing a 'Eight-two flash, three second pause' error, it could be due to damage to the temperature sensor wire or the temperature sensor resistance being out of range. The suggested solution is to replace the gas control.

Bradford White RG2PDV40SN Specifications

General IconGeneral
Capacity40 gallons
Energy Factor0.62
Weight140 lbs
Vent TypePower Vent
Fuel TypeNatural Gas
Warranty6 years
TypeGas Water Heater
Recovery Rate40 gallons/hour

Related product manuals