PROGRAMMING cont..
5
5.4
Setting Your Energy Saving Programs cont.
11
ADDITIONAL OPERATION FEATURES
CONTINUES ON PAGE
6
5.4.3
Entering Your Program cont..
3.
If you desire to use a different Quick Program Group or Individual Day program mode you can
change by pressing the DAY/TIME button to select another group in the following sequence,
Whole Week - Weekday - Weekend - Monday - Tuesday - Wednesday - Thursday -
Friday - Saturday - Sunday - Whole Week.
4.
Once you have finished your Quick Program Group or Individual Day selection. Press the or
buttons to change the time to the desired hour in one hour increments, press PROG
button. The minute portion of the setpoint time will begin flashing.
5.
Press the or buttons to change the time to the desired minute in 10-minute increments,
press PROG button. The SET TEMP will begin flashing.
6.
Press the or buttons to change the setpoint temperature to the desired setting in 1˚ F
increments (0.5˚ C), press PROG button. The thermostat will now display the DAY
setpoint time and temperature. Again, you will see the hour portion of the setpoint time
and the AM/PM indicator will be flashing.
7.
Follow steps 4 through 6 to set the setpoint times and temperatures for the DAY, EVE and
NIGHT setpoints for the Quick Program Group or Individual Day selection for the HEAT mode.
8.
Place the system switch in the COOL mode of operation. The display will show COOL. Follow
steps 2 through 6 to program the setpoint times and temperatures for the Quick Program
Group or Individual Day selection for the COOL mode.
9.
Repeat steps 3 through 8 for additional Quick Program Groups or Individual Day programming
as required.
NOTE: To erase all entered programs, current time of day, day of week and other user
settings, gently press RESET button using a paper clip or a small pencil tip. This will return
all Thermostat settings to their default values.
ADDITIONAL
OPERATION FEATURES
6
10
6.1
Review Set Temperature
1.
Press and hold or buttons. The current
setpoint temperature will be displayed in the place
of the current room temperature, and the indicator
SET TEMP will be displayed.
2.
The display will return to normal operating mode
when the or buttons are released. Continuing
to hold the or buttons for 3 seconds or longer will allow the user to temporarily
override the current programmed setpoint (See Temporary Program Override).
11
REMEMBER, this thermostat includes an automatic compressor protection
feature to avoid potential damage to the heat pump system from short cycling (See
Compressor Protection).
6.4
Efficient Recovery Mode (ERM™)
This thermostat is equipped with a special feature to maximize your energy savings by
utilizing the most effective source of heating or cooling to meet your program needs during
recovery from setback (or setup) temperatures. Our Efficient Recovery Mode (ERM
) feature
is designed to automatically calculate when to turn your first (heat pump) stage of your multi-
stage heating or cooling system to meet your upcoming comfort setpoint temperature setting.
While in normal operating mode, this feature will start calculating the start time for your first
stage (heat pump) two hours prior to the upcoming comfort setpoint temperature. During this
two hour time period it will monitor performance and control your system staging
requirements.The second (auxiliary) stages of heating or cooling will be available during this
2-hour period if required to meet extraordinary heating or cooling requirements.
6.5
Compressor Protection
This thermostat includes an automatic compressor protection feature to avoid potential
damage to the heat pump system from short cycling. This thermostat automatically provides
a 5-minute delay after turning off the heating or cooling heat pump output to protect the
compressor.
ADDITIONAL
OPERATION FEATURES
6
cont..
6.2
Temporary Program Override
6.3
Permanent Hold (Vacation) Mode
1.
Press and hold or buttons for 3 seconds. The
entire display will flash once and the SET TEMP
indicator will be flashing. Release the or
buttons and press the or buttons again as
desired to adjust the set temperature.
2.
The display will return to normal operating mode
after 15 seconds or you can press RESUME button.
3. The program indicator (MORN, DAY, EVE OR NIGHT) will be flashing in the display
indicating that a Temporary Program Override is in effect. The Temporary Program
Override will reset when the next setpoint time occurs.
1.
Press the HOLD button to permanently bypass the
program schedule. The current setpoint
temperature will be held permanently and HOLD
and TEMP will show in the display.
2.
Press the HOLD button again to return the
thermostat to normal program operation.
3. You can view or change your setpoint a t any time using the or buttons
(see Review Set Temperature or Temporary Program Override).