EasyManua.ls Logo

Brainchild BTC-9300 - 1-4 Keys and Displays

Brainchild BTC-9300
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm 1 IndicatorAlarm 1 Indicator
Alarm 2 / Output 2 IndicatorAlarm 2 / Output 2 Indicator
Process Value IndicatorProcess Value Indicator
Process Unit IndicatorProcess Unit Indicator
Upper Display,
to display process value,
menu symbol and error
code etc.
Upper Display,
to
display process value,
menu
symbol and error
code
etc.
Lower Display,
to display set point value,
parameter value or control
output value etc.
Lower Display,
to
display set point value,
parameter
value or control
output
value etc.
3 Silicone Rubber Buttons
for ease of control setup
and set point adjustment.
3 Silicone Rubber Buttons
for
ease of control setup
and
set point adjustment.
Set point
Value
Indicator
Set point
Value
Indicator
Output 1
Indicator
Output 1
Indicator
A1 A2 PV
LC
LF
SV
OUT
BTC-9300
Table 1.2 Keypad OperationTable 1.2 Keypad Operation
For a number with decimal point the
display will be shifted one digit right:
For a number with decimal point the
display
will be shifted one digit right:
-19999 will be displayed by:-19999 will be displayed by:
45536 will be displayed by:45536 will be displayed by:
-9999 will be displayed by:-9999 will be displayed by:
The unit is programmed by using three keys on the front panel. The available key functions are listed in following table.The unit is programmed by using three keys on the front panel. The available key functions are listed in following table.
Press and release quickly to increase the value of parameter.
Press and hold to accelerate increment speed.
Press and release quickly to decrease the value of parameter.
Press and hold to accelerate decrement speed.
Select the parameter in a direct sequence.
Allow access to more parameters on user menu, also used to Enter manual
mode, auto-tune mode, default setting mode and to save calibration data
during calibration procedure.
Select the parameter in a reverse sequence during menu scrolling.
Select the operation Mode in sequence.
Reset the front panel display to a normal display mode, also used to leave
the specific Mode execution to end up the auto-tune and manual control
execution, and to quit the sleep mode.
The controller enters the sleep mode if the sleep function ( SLEP ) is enabled
( select YES ).
By entering correct security code to allow execution of engineering programs.
This function is used only at the factory to manage the diagnostic reports.
The user should never attempt to operate this function.
Press
for at least 3 seconds
Press
for at least 6 seconds
Press
Press
Press
Press
Press
for at least 3 seconds
Up Key
Down Key
Scroll Key
Enter Key
Start Record Key
Reverse Scroll Key
Mode Key
Reset Key
Sleep Key
Factory Key
TOUCHKEYS FUNCTION DESCRIPTION
Reset historical values of PVHI and PVLO and start to record the peak process
value.
How to display a 5-digit number ?How to display a 5-digit number ?
9
1 4 Keys and Displays1 4 Keys and Displays
: Confused Character: Confused Character
Figure 1.4 Front Panel DescriptionFigure 1.4 Front Panel Description
Table 1.3 Display Form of CharactersTable 1.3 Display Form of Characters
-199.99 will be displayed by -199.9
4553.6 will be displayed by 4553
-199.99 will be displayed by -199.9
4553.6
will be displayed by 4553
For a number without decimal point
the display will be divided into two
alternating phases:
For a number without decimal point
the
display will be divided into two
alternating
phases:
A
E
I
N
S
X
B
F
J
O
T
Y
C
G
K
P
U
Z
c
H
L
Q
V
?
Dh
M
R
W
=
UM93001C

Table of Contents

Related product manuals