16 Tjekliste for sikkerhedstjek USA.fm • Page 35Baler B3 and B4
Check cable and socket
Visually check the supply cable and socket. There must be no
cracks or other defects, etc.
Defect OK
Check the emergency stop (A)
Doors (F) and (G) must be closed.
Activate the emergency stop button (A).
Then press the green start button (B).
It must not be possible for the baler to start.
Deactivate the emergency stop button (A).
Reset the baler with a single push of the green start button
(B), start the baler by pushing the green start button (B)
again.
Activate the emergency stop button (A).
The baler will stop immediately.
Deactivate the emergency stop button (A).
Reset the baler with a single push of the green start button
(B).
Defect
OK
Check the two-hand control (C) and (D)
Press on the finish indicator button (C) so the platen (H) goes
to the bottom position.
Open the doors (F) and (G), so the two-hand control (C) and
(D) activates and lights up.
First press the finish indicator button (C), then press button
(D).
The baler must not eject the bale.
Press buttons (C) and (D) simultaneously and costantly within
a time interval of ½ second.
The baler should start to eject the bale.
Close doors (F) and (G).
Defect
OK
Check door switch (M)
Open door (F) and press the green start button (B).
It must not be possible for the baler to start.
Close door (F) and press the green start button (B).
Open door (F) after about 10 seconds.
The baler will stop immediately.
It must not be possible to start the baler until door (F) has
been closed again.
Check that the two parts (M) of the door switch are complete
and not defective. (One of the parts of the door switch is on
the door (F), and the other is on the chamber of the baler).
Defect
OK