  • C
    carljonesSep 3, 2025
    What to do if auto-level doesn't take water and the light is off in Brasilia OPUS Coffee Maker?
    • J
      Jenna StephensSep 3, 2025
      If the auto-level does not take in water when it should, and the warning light is off on your Brasilia Coffee Maker, it might be because the probe is touching glass or earthed metal parts. Check and reposition it. Alternatively, the electronic control unit may be faulty; check and replace if necessary.
  • M
    Maria SmithSep 1, 2025
    Why the boiler does not heat up in Brasilia OPUS Coffee Maker?
    • C
      carol10Sep 2, 2025
      If the boiler does not heat up in your Brasilia Coffee Maker, it could be due to the resistance being interrupted. Replace it. Alternatively, no power may be reaching the resistance because the safety thermostat, the pressure switch, or the master switch are faulty. Check and replace the malfunctioning components if necessary.
  • J
    jacqueline07Aug 31, 2025
    What to do if auto-level takes in water when it shouldn't in Brasilia Coffee Maker?
    • B
      bakerteresaAug 31, 2025
      If the auto-level takes in water when it should not, and the level warning light is on in your Brasilia Coffee Maker, check the following: * The electrical connection between the level probe and the control unit may be interrupted. Check and restore the connection. * The electrical connection between the frame mass and the control unit may be interrupted. Check and restore the connection. * The level probe may be dirty. Clean it; when disassembling, do not take it off the isolator but remove it completely from the connector. * The electronic control unit may be faulty. Replace it.
  • T
    Theresa HartAug 29, 2025
    How to fix visual level not indicating real water level in Brasilia OPUS Coffee Maker?
    • J
      Jeffrey HowellAug 29, 2025
      If the graduated visual level does not indicate the real level of water in the boiler of your Brasilia Coffee Maker, the lower tube which connects the level to the boiler may be blocked. Disassemble and clean it.
  • A
    ashley68Aug 28, 2025
    Why the group does not heat up in Brasilia OPUS Coffee Maker?
    • J
      Jennifer DixonAug 28, 2025
      If the boiler is pressurized but the group does not heat up in your Brasilia Coffee Maker, it could be because air has not been removed from the boiler during the water heating phase. When the machine is cold, check that the air vacuum valve is not blocked shut and replace if necessary. Alternatively, the thermosiphon circuit may be partially blocked. Check the group supply and return tubes and connectors, and clean or replace them if necessary. Note: check purifier resin regeneration.
  • J
    Jennifer SpencerAug 26, 2025
    What to do if no water comes out of the group of Brasilia Coffee Maker?
    • C
      colebarbaraAug 27, 2025
      If no water comes out of the group in your Brasilia Coffee Maker, it could be due to several reasons: * The gicleur is blocked. Remove the gicleur cap, check, clean or replace it if necessary. * The injector is blocked. Remove and clean it, replace if necessary. Note: check purifier resin regeneration. * (only for versions with volumetric dosage) The doser inlet connector is blocked. Remove and clean it. * The solenoid valve does not open due to no power reaching the coil, an interrupted coil, or a blocked core. Check the solenoid valve, reset the electrical connections, or replace the coil. It is advisable to replace the whole solenoid valve.
  • J
    James GilbertAug 25, 2025
    What to do if the water level rises and leaks from the safety valve in Brasilia Coffee Maker?
    • L
      Larry CalhounAug 25, 2025
      If the level of water in the boiler continues to rise until leaking out of the safety valve in your Brasilia Coffee Maker, it could be due to several reasons: * The level probe may not be connected; check and replace if necessary. * There might be a foreign body inside the auto-level solenoid valve; check and replace if necessary. * A foreign body might be inside the seal site; check it. * The gasket may be worn; check and replace if necessary.
  • C
    Christopher McgeeAug 23, 2025
    Why no water comes out of the group and the pump is noisy in Brasilia OPUS?
    • A
      Amanda LeeAug 23, 2025
      If no water comes out of the group and the pump is noisy in your Brasilia Coffee Maker, it could be due to the mains or purifier taps being turned off. Ensure these taps are open. Another cause could be a blocked water inlet connector filter; remove and clean it.

Summary

General Instructions

Intended Use of the Machine

Defines the machine's primary purpose for making espresso and hot drinks.

Prohibited Uses

Lists forbidden actions and improper uses of the coffee machine.

Machine Use and Operation

Starting Up the Machine

Step-by-step guide on how to safely start the coffee machine.

Correct Coffee Supply Rules

Provides essential guidelines for preparing quality coffee and avoiding over-extraction.

Digit Version Coffee Preparation

Instructions for preparing coffee using the Digit version of the machine.

P Version Coffee Preparation

Instructions for preparing coffee using the P version of the machine.

Cappuccino Making Procedure

Step-by-step process for frothing milk and preparing a cappuccino.

Machine Cleaning

Troubleshooting Guide

Brasilia OPUS Specifications

General IconGeneral
BrandBrasilia
ModelOPUS
CategoryCoffee Maker
LanguageEnglish

Related product manuals