Page 32
Floor Level Guideline Adjustments
J
K
Wrong
OK
Bridge plate must be level and
must rest fully on UHMW slides.
Gap not permitted.
Platform too low.
Improper microswitch
adjustment may
result in serious
bodily injury and/or
property damage.
W
A
RNING
When adjusting microswitches, stop block
positioning and bridge plate positioning must
be viewed. A combination of adjustments may
be required to achieve a proper balance.
Adjust Unfold/Down and Up/Fold mi-
croswitches as outlined on page 30.
Stop Blocks:
The stop blocks must make full contact with
the inboard vertical edge of the vertical arms
when the platform is at floor level (see Photo D
on page 30). Stop blocks must be properly
positioned as detailed on page 30. Improper
stop block positioning can result in lift
damage.
Bridge Plate Positioning:
The bridge plate should be positioned so that
the outboard edge of bridge plate rests solidly
on the platform UHMW slides when at floor
level (shown in Photo J). There should be a
smooth (level) transition between the platform,
bridge plate and the base plate (see Photo J).
Photo K depicts the platform positioned too
low. An incorrect Up/Fold microswitch setting
can stop the platform from reaching the fully
raised position during the Up cycle. Or, the
Unfold/Down microswitch may be adjusted
improperly allowing the platform to unfold to a
position below floor level during the Unfold
cycle. The bridge plate does not make solid
contact with the base plate.
An incorrect Unfold/Down microswitch setting
can prevent the platform from unfolding fully
during the Unfold cycle. Or, the Up/Fold
microswitch may be adjusted improperly,
allowing the platform to raise above floor level
during the Up cycle. The bridge plate would
have an incline (uphill slope) from the platform
to the base plate creating an unlevel transition
between the platform, bridge plate and the
base plate (photo not available).
Floor Level Guidelines for Fixed
Inboard Roll Stop (Non-IB) Lift Models:
Note: See page 31 for Floor Level Guide-
lines for Automatic Inboard Roll Stop (IB) lift
models.