Page 51
Inspect eccentric shaft pins, bearing mounting
screw, washers and securement hardware for wear
or damage, positive securement and proper opera-
tion
Inspect torque tube cams for securement, wear or
damage
Inspect housing cam brackets for securement,
wear or damage
Inspect cylinder(s), hoses, ttings and hydraulic
connections for wear, damage or leaks
Inspect power cable
Resecure, replace damaged parts, lubricate or
correct as needed. See Carriage Ride Height
Adjustment in Service Manual.
Resecure, replace or correct as needed.
Resecure, replace or correct as needed.
Tighten, repair or replace if needed.
Resecure, repair or replace if needed.
1500
Cycles
Maintenance and Lubrication Schedule
4500
Cycles
Hydraulic Fluid (Pump) - Check level. Note:
Fluid should be changed if there is visible
contamination. Inspect the hydraulic system
(cylinder, hoses, ttings, seals, etc.) for leaks if
uid level is low.
Perform all procedures listed in previous section also
Use Braun 87010R (5606 aviation uid). Do
not mix with Dextron III or other hydraulic uids.
Check uid level with platform lowered fully. Fill to
maximum uid level indicated on reservoir (speci-
ed on decal). Do not overll. If uid level decal
is not present - measure 7/8" from the bottom of
ll tube to locate uid level.