PROBLEM POSSIBLE CAUSE WHAT TO DO
Display says
"Water tank
empty" but water
tank is full
Water tank not
fully inserted &
locked.
Push water tank in fully and lock latch closed.
No steam or
hot water
Machine is not
turned on or
up to operating
temperature.
Ensure the machine is plugged in and ready for use.
No hot water
Water tank is
empty.
Fill water tank.
No steam
Steam wand is
blocked.
Refer to 'Cleaning the Steam Wand', page 25.
The machine is ‘On’
but won't operate
Turn machine off. Wait for 60 minutes and turn
machine back on.
If problem persists, call Breville Consumer Support.
Steam pouring out
of group head
Turn machine off. Wait for 60 minutes and turn
machine back on.
If problem persists, call Breville Consumer Support.
Espresso only
drips from the
portafilter spouts,
restricted flow
Coffee is ground
too finely.
Adjust the grind size to a higher number to make the
grind size slightly coarser.
Espresso flows out
too quickly
The coffee is
ground
too coarsely.
Coffee beans are
stale.
Adjust the grind size to a lower number to make the
grind size slightly finer.
Use freshly roasted coffee beans with a 'Roasted On'
date and consume between 5-20 days after that date.
Coffee not hot
enough
Cups not pre-
heated.
Rinse cups under hot water outlet and place on cup
warming tray.
Milk not hot
enough (if making
cappuccino or latté
etc).
Increase the milk temperature in settings menu.
No crema
Coffee beans are
stale.
Use freshly roasted coffee beans with a 'Roasted On'
date and consume between 5-20 days after that date.