LOW-OIL MODULE INSTALLATION
The low-oil module is available in either a standard 2-wire version or a lamp indicator 5-wire version. They
are discussed separately below.
Standard Module 2-Wire Installation
1) After connecting the wires, install the module (Q1) to the flywheel finger guard with screw. Tighten
the screw to 55 lb-in (6.2 Nm).
2) Route the module ground wire through the clip (Q2) on the finger guard and between the ribs (Q3) in
the top of the cylinder. Pull the wire tightly, and then press it down to the cylinder as far as possible.
The wire must not interfere with the operation of the governor lever.
3) Route the wire beneath the blower housing mounting boss (Q4).
4) Attach the rocker switch ground wire under the control bracket mounting screw (Q5). Complete the
connections to the rocker switch as shown below.
Q1
Q2
Q3Q4
Q5