Lamp Indicator Module 5-Wire Installation
The wires and their associated circuits are shown below.
GRN = Ground
RED = Lamp Positive
YEL = Oil Sensor
BLK/WHT = Lamp Negative
BLK1 = Remote On/Off Switch
BLK2 = Ignition Coil
1) Connect the YEL wire to the oil sensor. Position the GRN wire terminal between the module and the
flywheel finger guard (R1), and then install the module (R2) to the finger guard with the screw.
Tighten the screw to 55 lb-in (6.2 Nm).
2) Connect the BLK1 wire to the remote on/off switch on the equipment, if equipped. Connect the BLK2
wire to the ignition coil. Make sure the wires are routed through the clip (R3) on the finger guard and
between the ribs (R4) in the top of the cylinder. Pull the wires tightly, and then press them down to
the cylinder as far as possible. The wires must not interfere with the operation of the governor lever.
3) Route the wires beneath the blower housing mounting boss (R5).
R2
R1
R3
GRN
RED
YEL
BLK/WHT
BLK1BLK2
R4
R5