Swimming Pool Heat Pump XHP
INSTALLATION
AND USER GUIDE
Illustrative photo
i
Read the instructions
EN

Questions and Answers

  • S
    Sean EspinozaSep 6, 2025
    What to do if the outgoing cooling water temperature is too low in my Brilix XHP 60?
    • J
      James PruittSep 7, 2025
      If the temperature of outgoing cooling water is too low in your Brilix Swimming Pool Heater, it is probably caused by insufficient water flow. Check the volume of water flow and whether or not the water passes through.
  • A
    Angela HicksAug 22, 2025
    What to do if my Brilix XHP 60 Swimming Pool Heater is not working?
    • T
      Troy ClayAug 22, 2025
      If your Brilix Swimming Pool Heater isn't working, there could be a few reasons. First, check the cable connection and the circuit breaker to ensure there is a power supply. Alternatively, the heat pump may be in standby mode, in which case you should start it up. Also, the water temperature might have reached the set value, putting the heat pump in constant temperature mode; check the water temperature setting. If the heat pump has just started, wait several minutes before starting it up. Finally, defrosting might be in progress, indicated by a “defrosting” message on the LED display.
  • S
    samanthablackburnSep 4, 2025
    What happens during the first stage of the frost protection system of Brilix XHP 60?
    • L
      Lindsey JordanSep 4, 2025
      During the first stage of the frost protection system of your Brilix Swimming Pool Heater, the pump will run automatically if the ambient temperature or the temperature of incoming water is too low.
  • S
    Sarah VasquezSep 2, 2025
    What happens during the second stage of the frost protection system in my Brilix XHP 60?
    • R
      racheltannerSep 2, 2025
      During the second stage of the frost protection system in your Brilix Swimming Pool Heater, the heat pump will start heating automatically if the ambient temperature or the temperature of incoming water is too low.
  • R
    rothbrendaSep 1, 2025
    Why is there a drop in water temperature when my Brilix XHP 60 Swimming Pool Heater is running in heating mode?
    • F
      Felicia JacobsSep 1, 2025
      If you notice a drop in water temperature while your Brilix Swimming Pool Heater is running in heating mode, it could be due to several reasons. First, the incorrect mode might be selected, so correct the running mode. Second, the values may indicate a fault; in this case, replace the defective cable controller with the LED display, then check the condition after the change of the running mode, and check the inlet and outlet water temperature. Finally, a controller failure could be the cause, so replace the defective main controller.
  • A
    Amber JacksonAug 30, 2025
    What to do if my Brilix Swimming Pool Heater has a communication error?
    • J
      James McclainAug 30, 2025
      If your Brilix Swimming Pool Heater shows a communication error, it is likely due to a wrong connection of cables. Check the connection of cables.
  • S
    Sophia WhiteAug 29, 2025
    What to do if my Brilix Swimming Pool Heater shows an inlet and outlet temperature difference error?
    • W
      wilsonbriannaAug 29, 2025
      If your Brilix Swimming Pool Heater displays an inlet and outlet temperature difference error, it may be caused by insufficient water flow or too low pressure difference. Check the volume of water flow and whether or not the water passes through.
  • M
    Michele HowardAug 27, 2025
    What to do if my Brilix Swimming Pool Heater has a short run?
    • K
      Kelly BeltranAug 28, 2025
      If your Brilix Swimming Pool Heater experiences a short run, it could be due to the fan not running, insufficient air ventilation, or a lack of coolant. Check the cable connections between the motor and the fan, and replace them if necessary. Also, check the location of the heat pump unit and remove any obstruction preventing good air ventilation. If the problem persists, replace or repair the heat pump unit.
  • J
    Janet LambertAug 27, 2025
    What to do if there is too much ice on the evaporator of my Brilix XHP 60 Swimming Pool Heater?
    • C
      Christopher RogersAug 27, 2025
      If there is too much ice on the evaporator of your Brilix Swimming Pool Heater, it may be caused by insufficient air ventilation or a lack of coolant. Check the location of the heat pump unit and remove any obstructions preventing good air ventilation. If that doesn't resolve the issue, consider replacing or repairing the heat pump unit.
  • P
    prestonjamesAug 25, 2025
    Why is my Brilix XHP 60 showing protection against high pressure?
    • C
      Carla PriceAug 26, 2025
      If your Brilix Swimming Pool Heater indicates protection against high pressure, it may be due to too much coolant or insufficient air flow. To fix this, remove the excess coolant from the heat pump system and clean the air exchanger.

Summary

Specification

Performance Curves

Heat Output, Input, and COP Curves

Graphical representations of heat output, input power, and COP versus air temperature for various models.

Dimensions

Physical Dimensions and Measurements

Table and diagram detailing the physical measurements of the heat pump models.

Installation Guide

Installation Illustration and Discharge Connection

Diagrams showing the physical setup, water connections, and discharge bypass.

Installation Position and Chemical Elements

Guidelines for selecting the installation position and the role of chemical elements.

Electrical Connection

Connection Diagrams

Detailed wiring diagrams for specific heat pump models (XHP 40, 60, 100, 140, 200).

Operation and Maintenance

Start-up, Winterization, and Restart Procedures

Steps for initial start-up, winter preparation, and post-winter restart.

Control Display Functions and Parameter Identification

Overview of control display functions and how to identify operating parameters.

Parameter Settings and Adjustments

Details and ranges for various operating parameters (0-8) and their settings.

Advanced Parameter Settings and Timers

Further parameter settings (9-H), mode identification, and timer configuration.

Setting Water Temperature and Clock

Procedures for setting water temperature, clock, locking, and timer functions.

Troubleshooting

Error Codes and Solutions

Table detailing fault codes, causes, and corresponding solutions for controller LED display errors.

Other Faults Without Display

Guide to troubleshooting common issues not indicated by error codes on the LED display.

Components and Parts

Schematic Representation and Component List

Exploded view diagram and a comprehensive list of all heat pump components.

Spare Parts Identification

Visual identification of key and ancillary spare parts for the heat pump.

Cabling Diagram and Part Replacement

Cabling diagram example and instructions for replacing heat pump parts.

Warranty and Service

Warranty Terms, Disposal, and Claims

Information on warranty conditions, safe product disposal, and service claims.

Brilix XHP 60 Specifications

General IconGeneral
CategorySwimming Pool Heater
Heating Capacity6 kW
Power Supply230 V / 50 Hz
Maximum Working Pressure3 bar
Temperature Range40 °C
ModelBrilix XHP 60