EasyManuals Logo

Brivis contour Service Manual

Brivis contour
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
Service Manual 32 – Contour 3 Series, Profiler & Advance – Approved Issue 5 Printed 2/13/2014 11:50:17 AM
45
Cooler Operation
(cont.)
Wash Service
(cont.)
Networker ON - No
call for Operation
Call for Fan
Operation
Call for Pump
Operation with
or without Fan
ServoSeal
opens
Delay = 20
seconds
(ServoTime)
Fan turns ON
ServoSeal
opens
Delay = 15
seconds
(ServoTime)
Inlet Valve
opens and
Tank fills
Water at low
level
Pump turns
ON
Pre-Wet time
starts
Pre-Wet
complete
Fan turns ON
if required
Networker turned
OFF or call for
pump and fan to
OFF
Delay = 60 minutes
(ServoCloseDelay)
ServoSeal
Closes 15
seconds
Delay = 45
seconds
(WashWaitTime)
Water Inlet Valve
opens 30 seconds
(WashTime)
Delay = 45
seconds

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brivis contour and is the answer not in the manual?

Brivis contour Specifications

General IconGeneral
BrandBrivis
Modelcontour
CategoryFreezer
LanguageEnglish

Related product manuals