Service Manual 32 – Contour 3 Series, Profiler & Advance – Approved Issue 5 Printed 2/13/2014 11:50:17 AM
64
Cooler Operation
(cont.)
Pump Operation
(cont.)
The following checks are required if the pump has power, but will not operate, or is
not pumping sufficient water to the filter pads.
Mechanical Checks
Check that the tank water level is correct.
Check the water distribution piping is not blocked.
Dismantle the pump as per the instructions.
Check and clear the lower pump housing of any obstruction.
Check the pump impellor is not damaged, and can rotate within the upper pump
housing.
Replace upper pump housing assembly, if impellor damaged or jammed.