TABLE 4.5
Technical specifications MBP-U
Firing rate 0.65 0.75 0.85
Input (BTU/h) 90 500 104 500 118 000
Capacity (BTU/h) 76 000 87 000 98 000
Stack draft (chimney)
BECKETT BURNER, CHIMNEY INSTALLATION
Static disc, model
Nozzle (Delavan) - 100 PSIG pump pression 0.65 X 80W 0.75 X 80W 0.85 X 80W
Volts - Hertz - Phase
Operating voltage range
Rated current (Amps)
Motor (HP) / number of speeds
Blower wheel size (in.)
Filter quantity and size
Blower Speed at 0.25"w.c. Static Pressure Med-Lo Med-Lo Med-Hi
Blower Speed at 0.50"w.c. Static Pressure
Med-Lo
Med-Hi
High
10 X 8
(1) 20" X 20"
104 - 132
12
BLOWER DATA
1/3 HP, 4 speeds
ELECTRICAL SYSTEM
115 - 60 - 1
SR-65-F3 (Insertion tube 5 5/8)
3 3/8" #3384
Model : MBP-U
RATING AND PERFORMANCE
-0.02" WC
15