CHAPTER 4 HP-GL/2 - 15 
SC - Scale 
<HP-GL/2> 
SC [ X
min,  Xmax, Ymin, Ymax [, type ]] [;] (Type = 0) 
SC [ X
min,  Xmax, Ymin, Ymax , type [ left, bottom]] [;] (Type =1) 
SC [ X
min
, X 
factor
, Y 
min
 Y 
factor
 [, type ]] [;] (Type = 2) 
X
min ; X coordinate of P1    Xmax ; X coordinate of P2 
Ymin ; Y coordinate of P1    Ymax ; Y coordinate of P2 
Type ; type of scaling 
Left ; percentage of unused space to be left to the left of the scaling area 
bottom ; percentage of unused space to be left below the scaling area 
X
factor ; number of graphics units per user unit on the x-axis. 
Y
factor ; number of graphics units per user unit on the y-axis. 
  This command turns scaling on and establishes a user unit coordinate system.    The coordinate system is 
specified relative to the points P1 and P2.    The origin need not necessarily be at P1.    Three different types 
of scaling are available. 
  The technical terms, user unit and graphics unit, as used in this manual are defined as follows: 
   User unit    : the unit of the coordinates set by the SC instruction. 
   Graphics unit    : the unit(1/1016 of an inch) of the coordinates not set by the    SC instruction. 
  All coordinates are in user units. 
  Coordinate values for X
min,    Xmax, Ymin, and Ymax are given as real numbers. 
  X
min
, Y
min
, X
max
 and Y
max
 specify the range of the X- and Y-axes.    X
min
 and Y
min
 value should be P1 and 
X
max
 and Y
max
 should be P2. 
  X
min must be different from Xmax, and Ymin must be different from Ymax. 
  Using this instruction without a parameter field turns the scaling off.   
  Type can be 0, 1 or 2, which select scaling types known as anisotropic, isotropic and point factor scaling 
respectively. 
  Type 0 scaling (anisotropic scaling, the default) allows you to specify different sized x-axis and y-axis units.   
Hence the area specified by X
min,    Xmax, Ymin, and Ymax will occupy the entire area defined by P1 and P2. 
P1 (0,0)
P2 (7,6)
 
  left and bottom settings have no effect in type 0 scaling. 
  Type 1 scaling (isotropic scaling) forces x-axis and y-axis units to be the same size.    As a result the area 
specified by X
min,    Xmax, Ymin, and Ymax (the isotropic area) may not fit exactly into the rectangular area 
defined by P1 and P2. 
P1
(0,0)
(6,7)
P2