Oil pressure below minimum oil pressure on the ground
If noticed on ground, immediately stop the engine and determine the cause.
Inspect the complete lubrication system, trace cause and rectify.
If the oil pressure falls below the minimum value up to max. 0.5 bar (7.25 psi) and for max.
1 min., the cause must be determined.
Table 5: Oil pressure below minimum permissible oil pressure up to max. 0.5 bar
(7.25 psi) max. 1 min. in flight
Step
Procedure
1 Inspect all oil lines for restrictions and clear passage.
2
Verify oil quantity.
3 Inspect pressure sensor and connector.
4
Inspect indicating instrument to specifications of the manufacturer, replace
as required.
5
Inspect crankcase pressure (See Installation Manual (IM), latest issue).
Effectivity: 916 i A / C24
Edition 0/Rev. 1
05–50–00
Page 35
December 01 2023