Page #172 background imageLoading...
Page #172 background image
BRP-Rotax
MAINTENANCE MANUAL LINE
Installation
NOTICE
Always replace both spark plugs of a cylinder and do not interchange spark
plugs between cylinders.
NOTICE
Silicone heat compound at the ground electrode or the head area can lead to igni-
tion problems. Apply heat compound sparingly and do not apply to the first three
threads.
Step
Procedure
2 Apply small amount of silicone heat compound to spark plug thread and
tighten spark plug to 16 Nm (142 in. lb) on the cold engine.
FUSE BOX
General note Check plug connections and fuse plugs (fuses). Check LED indicators.
12–20–00
Page 48
December 01 2023
Effectivity: 916 i A / C24
Edition 0/Rev. 1