MAINTENANCE MANUAL LINE
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance (re-
quirement after the first 25 hours
of operation)
25* 50 100 200 400 600 1000
18) Crankcase pressure check
Check the crankcase pressure.
Test pressure________mbar (psi)
(1
use of leaded fuel (AVGAS) more
than 30% of operation
X
(1
See Installa-
tion Manual
Chap.
79–00–00
19) Replacement of the rocker arm bushing
Replace the rocker arm bushing X
See Heavy
Mainte-
nance
Chap.
72–30–00
Returning engine to service
On the engine identified as per Check List/Maintenance Schedule, a 25 hr; 50 hr; 100 hr; 200 hr; 400 hr; 600
hr; 1000 hr
(circle correct maintenance interval) was performed.
Check at______hr. TSN / TSO (circle applicable engine time) _____ was carried out according to recommen-
dations of the engine manufacturer and was recorded in the Engine Log book.
Location, Date_______________________
Inspector___________________________
Aircraft technician_____________________
Certificate No.______________________
05–20–00