BRP-Rotax
MAINTENANCE MANUAL LINE
NOTICE
Use only coolant as recommended in the current Operators Manual (OM).
Step
Procedure
9
Check if the relief pressure lies within following limits for both radiator cap
types.
Min. relief pressure: 1.2 bar (17.4 psi)
Max. relief pressure: 1.6 bar (23.2 psi)
10 If relief pressure is higher than the max. or lower than the min. relief pres-
sure, replace the radiator cap with new and repeat the test.
11
If min. pressure cannot be achieved, or pressure cannot be maintained -
check the system to find the leakage.
Figure 5.22
m WARNING
Non-compliance can result in serious injuries or death!
For static, on-ground testing of the coolant system only. Do not run the engine while
configured for pressure testing.
Effectivity: 916 i A / C24
Edition 0/Rev. 1