ENVIRONMENTAL NOTE
Protect the environment.
Do not harm the environment by spilling oil. Dispose of oil in an envi-
ronmentally friendly manner.
4.3) Engine start
m WARNING
Non-compliance can result in serious injuries or death!
Do not start the engine if any person is near the engine.
Engine start
Maintenance CAN Bus (A/B) must not be used during flight.
B.U.D.S. aircraft USB-to-CAN converter must be disconnected.
Step Step Description Procedure
1 Engine
Pre-heating (below
- 10 °C / 14 °F ambi-
ent temperature)
Example
(Symbolic)
2 Activate Fuel pump
1 and check func-
tionality of fuel
pump 2
HIC A: A connection between
Terminal 3 and Terminal 9 at 916
i Type A, or at 916 i Type C24
Terminal E and F, will power Fuel
pump 1.
HIC B: A connection between
Terminal 3 and Terminal 11 at
916 i Type A, or at 916 i Type
C24 AC-DC Converter Terminal
X4.C and X4.D, will power Fuel
pump 2.
Example
(Symbolic)
Fuel pump 1: ON
Fuel pump 2: OFF
NOTICE
Only switch on one fuel pump when starting the engine. Switching
on both fuel pumps can lead to a bad start behavior.
Page 4-6
December 01 2023
BRP-Rotax Effectivity: 916 i A / C24
Edition 0 / Rev. 1

Other manuals for BRP ROTAX 916 i A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP ROTAX 916 i A Series and is the answer not in the manual?

BRP ROTAX 916 i A Series Specifications

General IconGeneral
BrandBRP
ModelROTAX 916 i A Series
CategoryEngine
LanguageEnglish

Related product manuals