Effectivity: 916 i A / C24
Edition 0 / Rev. 1
BRP-Rotax Page 4-21
December 01 2023
NOTE
The ECU needs to deactivated before the fuel pumps. Shutting
of the engine by deactivating the fuel supply may result in fault
and failure entries in the ECU. Shutting down the engine by
shutting of the fuel pumps is only allowed in emergency
situations.
Step Step Description Procedure
5 Deactivate Fuel
pumps
HIC A: Disconnect Terminal 3
and Terminal 9 at 916 i Type A,
or at 916 i Type C24 Terminal E
and F to turn OFF Fuel pump 1.
HIC B: Disconnect Terminal 3
and Terminal 11 at 916 i Type A,
or at 916 i Type C24 AC-DC
Converter Terminal X4.C and
X4.D to turn OFF Fuel pump 2.
Example (Symbolic) Fuel pump 1: OFF
Fuel pump 2: OFF