EasyManua.ls Logo

BRUEL & KJAER 1617 User Manual

BRUEL & KJAER 1617
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instruction
Manual
Band Pass Filter Type
1617
'
--
--
-
,-
::::::
-
~:
..
r-
'-
C
-"'-
"
..
T
..
. . _ .
..
± .
::-
l:
::
033-0143
1617
The Type 1 61 7
has
50
third
-octave
filter
bands
with
centre
frequencies
2
Hz
to
160
kHz, 41
overlapping
octave
filter
bands
from
2 Hz
to
20
kHz, A, 6 , C, D-
weighting
networks
, and a
Linear
pass band 1 Hz
to
200
kHz. The
filter
pass bands
fulfil
the
most
severe
standards,
IEC
225
-
1966
, DIN
45651
(1
/ 1-oct) and
45652
(1
/ 3-oct).
and
ANSI 51 .
11
-
1966
Class
II
(1
/ 1-oct)
and Class
III
(1
/
3-oct)
.
In
addition
to
facilities
for
filter
scanning
controlled
by
6 & K Level Recorders,
there
is a
built-in
interface
to
the
proposed
IEC
standard
via
which
full
control
can
be
exer-
cised.
An
internal
control
system
is able to
programme
the
averaging
times
of
the
mea-
suring
i
nstrument
that
is
connected
to
the
Type
161
7 so
that
the
optimum
6T
product
is
maintained
during
a
frequency
scan.
~
Bruel &
Kjcer

Other manuals for BRUEL & KJAER 1617

Question and Answer IconNeed help?

Do you have a question about the BRUEL & KJAER 1617 and is the answer not in the manual?

BRUEL & KJAER 1617 Specifications

General IconGeneral
BrandBRUEL & KJAER
Model1617
CategoryLaboratory Equipment
LanguageEnglish

Summary

Band Pass Filter Type 1617 Overview

General Features and Uses

Key features, capabilities, and applications of the Type 1617 filter.

Special Considerations in Frequency Analysis

Filter Definitions and Bandwidth

Explains filter concepts like ideal filter, bandwidth, octaves, and specified frequencies.

RMS Measurement and Statistical Accuracy

Discusses accuracy in RMS measurement and statistical properties of stationary signals.

Practical Analysis of Stationary Signals

Details parameters for analyzing stationary signals like averaging time and recording modes.

Controls

Front Panel Controls

Description of the controls located on the front panel of the Type 1617.

Rear Panel Connections

Details the various input/output connectors and switches on the rear panel.

Operation

Preliminary Adjustments

Steps for setting up line voltage, fuses, and grounding before operation.

Operation with Measuring Amplifiers Alone

How to use the filter independently with measuring amplifiers.

Operation with Measuring Amplifier and Level Recorder

Guidance for spectrum analysis using amplifiers and Level Recorders.

Operation with Other Brüel & Kjær Instruments

Using the filter with sound level meters and vibration meters.

Digital Data Transfer and Remote Control

Instructions for controlling and transferring data via the IEC interface bus.

Digital Programming Examples

Examples of controlling the Type 1617 using external programming devices.

Related product manuals