3.
Adjust
the
Band Pass
Filter
as described in section
3.3
.1/ 3
with
the
following
changes
:
AVERAGING CONTROL, Program
and
Min
.
Time
switches
AVERAGING TIME
switch
(rear panel)
Select
a
program
to
suit
the
current
measuring
as-
signment
. For a
more
comprehens
ive
description
on use
of
the
programs
see
section
4.2
.2 .
"
Variable
"
4 .
Adjust
the
Level Recorder as described in section 3 .3 .1/ 4 .
RECORDING
MODE
: "
DC"
5. Calibrate
the
pen
displacement
of
the
Recorder according
to
section
3 .3 .1/
5,
or
6
as
required
.
6 .
Synchronize
the
paper
transport
as
descr
ibed in section 3 .3 .1/ 8 , 9 ,
10,
11
, and
12
.
7 .
Apply
the
signal
to
be analyzed
to
the
input
terminal
of
the
Measuring
Amplifier
.
8 .
Switch
the
Level Recorder
PEN
DRIVE " On" .
9.
Switch
the
Band Pass Fi
lter
RANGE
to
the
frequency
range
required
.
10
.
Turn
the
MANUAL
FILTER SELECTOR
to
the
first
band
of
the
analysis
.
11
.
Start
analysis and recording by pushing
the
right-hand
FILTER CONTROL
MODE
switch
to
"Run
" .
The averaging time in
the
Measuring
Amplifier
is
automatically
switched
to
the
pro-
grammed
value
for
the
frequency
band being
measured
. The Level Recorder is
held
stati
onary
fo
r a period
of
five
times
the
averaging
time,
while
the
rectifier
circuits
and
the
pen
position
stabilize on
the
signal level. The
Measuring
Amplifier
is
then
switched
to
an averaging
time
of
10
seconds (or longer)
to
hold
the
pen
deflection
,
while
the
Recorder
starts
and
drives
forward
a distance
proportional
to
the
step size
selected,
to
give a plot
of
the
level in
that
band. Then
the
Filter steps
to
the
next
fre-
quency
band and
the
programmed
averaging
time
for
that
band is selected
while
the
Recorder reverts
to
its hold
function
.
3.3.3.
Fixed
averaging
time
analysis
with
the
Level
Recorder
Type
2307
22
1.
Connect
the
instrumentation
as
shown
in Fig .3 .9 .
2.
Adjust
the
Measuring
Amplifier
as described in its
Instruction
Manual,
and in sec-
tion
3 .3 .1/ 2 .
3 .
Adjust
the
Band Pass
Filter
as described in section
3.3
.1/
3.
4 .
Make
the
preli
minary
adjustments
and load Range
Potentiometer
,
frequency
cali-
brated paper,
etc
., as described in
the
Level Recorder
Instruction
Manual,
operations
section
, and
adjust
the
controls
of
the
2307
as
follows
:
POTENTIOMETER