mally
is
adequate
to
provide
air
for
combustion,
ven¬
tilation,
and
draft
hood
dilution*
*
If
the
uneonfined
space
is
within
a
building
of
unusually
tight
construction,
air
for
combustion,
ven¬
tilation,
and
draft
hood
dilution
shall
be
obtained
from
outdoors
or
from
spaces
freely
communicating
with
the
outdoors.
Under
these
conditions
a
per¬
manent
opening
or
openings
having
a
total
free
area
of
not
less
than
one
square
inch
per
5,000
Btuh
of
total
input
rating
of
all
appliances
shall
be
provided.
Ducts
used
to
convey
makeup
air
from
the
outdoors
shall
be
of
the
same
cross-sectional
area
as
the
free
area
of
the
openings
to
which
they
connect
Such
ducts
connected
to
the
outside
air
only
may
be
connected,
to
the
cold
air
return
of
the
heating
system.
The
minimum
dimension
of
rectangular
air
ducts
shall
be
not
less
than
3
inches.
All
air
from
inside
building:
The
confined
space
shall
be
provided
with
two
per¬
manent
openings,
one
near
the
top
of
the
enclosure
and
one
near
the
bottom,
Each
opening
shall
have
a
(
free
area
of
not
less
than
one
square
inch
per
1,000
V,-
Btuh
of
the
total
input
rating
of
all
appliances
in
the
enclosure,
freely
communicating
with
interior
areas
having
in
turn
adequate
infiltration
from
the
outside.