2. Set temperature rise.
Furnace must operate within range of temperature rise
specified on the unit rating plate. Determine the air tem-
perature rise as follows.
a. Place duct thermometers in return and supply ducts as
near furnace as possible. Be sure thermometers do not
"see" heat exchangers so that radiant heat does not affect
thermometer readings. This is particularly important
with straight-run ducts.
b. When thermometer readings stabilize, subtract return-air
temperature from supply-air temperature to determine
temperature rise.
c. Adjust air temperature rise by adjusting blower speed.
Increase blower speed to reduce temperature rise. De-
crease blower speed to increase temperature rise.
WARNING: Disconnect the electrical power before
changing the speed tap. Failure to follow this warning
could result in personal injury.
d. To change blower motor speed selections for heating
mode remove blower motor lead from control board
HEAT terminal. (See Fig. 11.) Select desired blower
TABLE 7—MODEL 373LAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT RATE*
(TABULATED DATA BASED ON ALTITUDE UP TO 2000 FT AND 23,000 BTUH PER BURNER)
GAS HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.56 0.58 0.60 0.62 0.64 0.66 0.68 0.70 0.72
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
860
40
41
3.2
3.5
40
41
39
3.3
3.6
40
41
39
3.4
3.7
3.2
40
41
39
3.5
3.8
3.3
40
38
39
3.7
3.2
3.4
40
38
39
3.8
3.3
3.5
38
39
3.4
3.6
37
38
39
3.2
3.5
3.8
37
38
3.2
3.6
875
41
42
3.3
3.7
40
41
3.2
3.5
40
41
3.3
3.6
40
41
39
3.4
3.7
3.2
40
41
39
3.5
3.8
3.3
40
38
39
3.6
3.2
3.4
40
38
39
3.8
3.3
3.5
38
39
3.4
3.6
38
39
3.4
3.7
890
41
42
3.2
3.6
41
42
3.4
3.7
40
41
3.2
3.5
40
41
3.3
3.6
40
41
39
3.4
3.7
3.2
40
41
39
3.5
3.8
3.3
40
39
3.6
3.4
40
38
39
3.7
3.2
3.5
40
38
39
3.8
3.3
3.6
905
42
3.5
41
42
3.2
3.6
41
42
3.4
3.7
40
41
3.2
3.5
40
41
3.3
3.6
40
41
39
3.4
3.7
3.2
40
41
39
3.5
3.8
3.3
40
39
3.6
3.4
40
38
39
3.7
3.2
3.5
920
42
3.4
42
3.5
41
42
3.2
3.6
41
42
3.4
3.7
40
41
42
3.2
3.5
3.8
40
41
3.3
3.6
40
41
39
3.4
3.7
3.2
40
41
39
3.5
3.8
3.3
40
39
3.6
3.4
935
42
3.3
42
3.4
42
3.5
42
41
3.6
3.2
42
41
3.7
3.4
42
40
41
3.8
3.2
3.5
40
41
3.3
3.6
39
40
41
3.2
3.4
3.7
39
40
41
3.3
3.5
3.8
950
42
3.2
42
3.3
42
3.4
42
3.5
42
41
3.6
3.2
42
41
3.7
3.3
42
40
41
3.8
3.2
3.5
40
41
3.3
3.6
39
40
41
3.2
3.4
3.7
965
43
3.7
42
3.2
42
3.3
42
3.4
42
3.5
42
41
3.6
3.2
42
41
3.7
3.3
42
40
41
3.8
3.2
3.4
40
41
3.3
3.5
980
43
3.6
43
3.7
42
3.2
42
3.3
42
3.4
42
3.5
42
41
3.6
3.2
42
41
3.7
3.3
42
44
41
3.8
3.2
3.4
995
43
3.5
43
3.6
43
3.8
42
3.2
42
3.3
42
3.4
42
3.5
42
41
3.6
3.2
42
41
3.7
3.3
1010
43
3.4
43
3.5
43
3.6
43
3.6
42
3.2
42
3.3
42
3.4
42
3.5
42
41
3.6
3.2
1025
43
44
3.3
3.8
43
3.4
43
3.5
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
42
3.5
1035
43
44
3.2
3.7
43
44
3.3
3.8
43
3.4
43
3.6
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
1055
44
3.6
43
44
3.2
3.7
43
44
3.3
3.8
43
3.5
43
3.6
43
3.7
43
3.8
42
3.2
42
3.3
1070
44
3.5
44
3.6
43
44
3.3
3.7
43
44
3.4
3.8
43
3.5
43
3.6
43
3.7
43
3.8
42
3.2
1085
44
3.4
44
3.5
43
44
3.2
3.6
43
44
3.3
3.7
43
3.4
43
3.5
43
3.6
43
3.7
43
3.8
1100
44
3.3
44
3.4
44
3.5
43
44
3.2
3.6
43
44
3.3
3.7
43
3.4
43
3.5
43
3.6
43
3.7
*For size 060135 only, deduct 0.1-in. wc from manifold pressure shown in table due to 22,500 Btuh per burner input. If resultant manifold pressure falls below 3.2-in. wc,