Bryant 394U - Checking Furnace Controls and Operation

Bryant 394U
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Light
Main
Burners
using
the
procedure
contained
on
the
metal
Lighting
Instruction
Plate
ΕΕ
to
the
front
of
the
furnace.
E
Adi
just
Gas
Rate.
Set
the
room
thermostat
on
call
for
‘heat
and
adjust
the
gas
rate.
There
will
be
approx-
imately
30
seconds
delay
before
the
valve
opens.
l.
City
Gases
Measure
gas
input
at
the
meter.
The
burners
are
equipped
with
fixed
Orifices,
sized
to
produce
the
rated
input
shown
on
the
rating
plate.
measured
and
rated
input
are
not
approximately
the
same,
the
gas
piense
regulator
may
be
ad-
justed
as
follows:
a.
To
increase
input:
Turn
gas
pressure
regulator
|
adjusting
screw
‘clockwise.’
(Adjusting
screw
is
-
concealed
under
the
regulator
sealing
cap.)
b.
To
decrease
input:
Turn
the
adjusting
Screw
!
‘counter-clockwise.’
The
manifold
pressure
should
be
set
as
follows:
Natural
Gas
3
inches
w.c.
Maximum
pressure
departure
from
recommended
pres-
sure
should
be
plus
or
minus
0.3
inches
w.c.
2.
Propane
Gas
These
units
are
not
equipped
with
gas
pressure
regulators.
Burner
orifices
are
sized
to
give
the
rated
input
at
a
manifold
pressure
of
11
inches
w.c.
Since
meters
are
not
normally
used
with
propane
gas,
it
will
be
necessary
in
most
cases
to
check
the
manifold
pressure
and
adjust
the
regu-
lator
at
the
supply
tank
to
provide
a
pressure
of
1
inches
w.c.
3.
If
the
input
in
item
(1)
or
(2)
above
is
too
great
or
too
little,
install
new
orifices.
Be
sure
the
rated
input
is
obtained
without
any.
ΠΕ
ΝΕ
in
manifold
gas
poem
LA
M
|
Adiust
Main
Bond
Plame:
M
“The:
main’
ac:
flame
.
Should
be
clear
blue,
almost
transparent,
with
a
well-
defined
inner
cone.
If
there
is
insufficient
primary
air,
the
flame
will
be
yellow-tipped.
If
there
is
too
p
much
primary
air
the
flame
will
be
well-defined,
but
with
a
tendency
to
dance
or
lift
off
the
burner
ports.
Ἱ.
Allow
furnace
to
operate
15
minutes.
2.
Adjust
each
burner
by
closing
the
air
shutter
until
a
slight
yellow
tip
appears
on
the
flame;
then
open
the
air
shutter
just
enough
to
clear
the
yellow
from
the
flame.
-
I1-
-
CHECK
CONTROLS
Bryant
Diaphragm
Gas
Control
Valve
if
not
already
checked
when
lighting
the
main
burner,
check
the
proper
operation
of
this
valve
by
moving
the
room
thermostat
pointer
above
and
below
room
temperature
and
observe
that
the
main
burners
light
on
call
for
heat
and
go
off
when
the
pointer
is
moved
below
the
room
temperature
setting.
Remember,
there
will
be
approximately
a
30
second
delay
on
ignition
and
.
extinction.
Automatic
Pilot
To
check
the
pilot
operation
follow
the
instructions
below:
I.
Set
the
room
thermostat
on
call
for
heat.
There
is
a
delay
before
burners
light.
2.
After
burners
have
lit,
close
the
pilot
gas
valve.
3.
The
automatic
pilot
will
break
the
electrical
circuit
to
the
gas
valve
and
the
burners
will
shut
off.
There
is
a
delay
before
burners
shut
off.
Limit
Control
This
control
functions
to
shut
off
the
gas
if
the
furnace
becomes
over-heated..
The
method
of
checking
satisfactory
operation
is
left
to
-
the
discretion
of
the
installer.
Extreme
caution
should
always.
be
employed.
ME
Blower
Adjustmerit
lt
is
ρθρα
that
the
blower
speed
be
adjusted
before.
there
is
any
ΗΕ
to
adjust
the
fan
control
switch.
The
blower
speed
is
set
at
the
factory.
‘Under
no
circumstances
should
the
temperature
rise
across
the
furnace
be
allowed
to
exceed
105
degrees
F
After
the
desired
air
flow
or
temperature
rise
across
the
furnace.
has.
been
obtained,
.
the
AMOR
Should
be
complete.
|
Bryant
has
introduced
a
new
concept
in
n
controls
in
the
394
furnace.
The
394
incorporates
the
tried
and
proven
822
Relay
for
fan
control.
The
822
has
a
field
adjustable
dif-
ferential.
The
‘‘max
off”
setting
on
the
dial
is
for
the
longest
''off'
time
and
shortest
‘‘on’’
time.
.
394U