Form No. PDS 561C.18.6
ELECTRIC
AIR CONDITIONER
561C (60 Hz)
Sizes 018 thru 060
Model 561C Energy-Efficient Air Conditioners incorporate inno-
vative technology to provide reliable summer cooling perfor-
mance. Built into these units are the features most desired by
homeowners today including SEER ratings of up to 11.5 when
used with components designated by manufacturer. All models
are listed with UL, c-UL, ARI, CEC, and CSA-EEV.
AVAILABLE OPTIONS
UNIT DESIGN
—Copper tube, enhanced sine wave aluminum
fin coil is designed for optimum heat transfer. Vertical air dis-
charge carries sound and hot condenser air up and away from
adjacent patio areas and foliage. Heat pump-style base pan for
easy removal of water, dirt, and leaves.
ELECTRICAL RANGE
—All units are offered in 208–230v sin-
gle phase. Three-phase units are available from 030 through
060 sizes in 208/230v and from 036 through 060 sizes in 460v.
WIDE RANGE OF SIZES
—The 561C is available in 7 nominal
sizes from 018 through 060 to meet the needs of residential and
light commercial applications.
WEATHER-PROTECTIVE CABINET
—The steel panels are
protected with a galvanized coating then covered with a layer of
zinc phosphate. A modified polyester powder coating is then
applied and baked on, providing each unit with a hard, smooth
finish that will last for many years.
All screws on cabinet exterior are coated for a long-lasting, rust-
resistant, quality appearance.
TOTALLY ENCLOSED FAN MOTOR
—Means greater reliability
under rain conditions and dependable performance for many
years. The permanent-split-capacitor-type motor was designed
for optimum efficiency. Then, under extreme conditions, the
motor was tested and qualified to help ensure the greatest reli-
ability.
APPLICATION VERSATILITY
—The unit can be combined with
a wide variety of evaporator coils and blower packages to pro-
vide quiet, dependable comfort. Unit can be installed on a roof
or at ground level on a slab.
EXTERNAL SERVICE VALVES
—The service valves are brass,
front seating type. The 561C has sweat field connections.
Valves are externally located so refrigerant tube connections
can be made quickly and easily. Each valve has a service port
for ease of checking operating refrigerant pressures.
EASY SERVICEABILITY
—One access panel provides access
to electrical controls and compressor. Removal of wire dome
gives access to fan motor and removal of the top gives access
to the coil.
COMPRESSOR PROTECTION
—Each compressor is pro-
tected with internal temperature- and current-sensitive over-
loads. An internal pressure relief valve provides high-pressure
protection to the refrigerant system.
LIMITED WARRANTY
—Standard 1-year warranty on parts,
with an additional 4-year warranty on compressor.
Question and Answer IconNeed help?

Do you have a question about the Bryant ELECTRIC AIR CONDITIONER 561C and is the answer not in the manual?

Bryant ELECTRIC AIR CONDITIONER 561C Specifications

General IconGeneral
BrandBryant
ModelELECTRIC AIR CONDITIONER 561C
CategoryAir Conditioner
LanguageEnglish

Summary

Electric Air Conditioner Features

Unit Design and Construction

Coil design, airflow, cabinet protection, and motor reliability.

Electrical and Application Specs

Electrical ranges, sizes, versatility, serviceability, and protection.

Warranty Information

Details on parts and compressor warranty coverage.

Unit Dimensions

Dimensions Table

Table of physical measurements for various unit sizes and series.

Performance Charts

Piston Identification Chart

Chart listing piston identification numbers for each unit size.

Recommended Tube Diameters

Guidelines for liquid and vapor tube diameters based on length.

Sound Power Data

Sound power levels in decibels across octave bands.

Technical Specifications

Electrical and Compressor Details

Voltage, amperage, refrigerant type, compressor protection details.

Condenser Coil, Fan, and Optional Equipment

Coil specs, fan motor details, and list of available accessories.

Accessory Usage Guidelines

Accessory Requirement Table

Table indicating accessory needs for low-ambient and long-line applications.

Accessory Descriptions and Usage

Ball Bearing Fan Motor

Fan motor with ball bearings for improved speed reduction and lubrication.

Coastal Filter

Mesh screen to protect coil from salt damage in coastal areas.

Compressor Start Assist

Capacitor/Relay or PTC type for improved compressor motor start-up.

Cycle Protector

Timing device to prevent rapid compressor recycling by providing a delay.

Evaporator Freeze Thermostat

Switch to stop unit operation if evaporator reaches freeze-up conditions.

Filter Drier

Device for removing contaminants from refrigerant in a 1-direction flow.

High-Pressure Switch

Switch that cycles compressor off if refrigerant pressure rises too high.

Inlet Grille Kit

Enhanced inlet grille for residential units for weather protection.

Liquid-Line Solenoid Valve

Electrically operated valve to stop/start refrigerant liquid flow for system performance.

Low-Ambient Controller

Head-pressure controller to cycle outdoor fan for condensing temperature.

Low-Pressure Switch

Switch that cycles compressor off if refrigerant pressure drops too low.

MotorMaster Control

Fan speed control device responding to saturated condensing temperature.

Sound Hood

Wraparound cover to reduce compressor noise level.

Thermostatic Expansion Valve (TXV)

Modulating valve metering refrigerant flow based on evaporator superheat.

Time-Delay Relay

Relay that continues indoor blower operation after compressor cycles off.

Winter Start Control

Delay relay to permit start-up for cooling under low-load conditions.

Combination Ratings

Ratings Table Overview

Table showing capacity, ratings, and EERA for various indoor/outdoor unit combinations.

Detailed Cooling Capacities

Cooling Capacity Tables

Capacity data for different condenser/evaporator air temperatures and indoor sections.

Condenser Only Ratings

Condenser Performance Ratings

Ratings for condenser performance at various SST and entering air temperatures.

System Design Considerations

Installation and Operation Guidelines

Notes on outdoor installation, temperature limits, elevation, and wiring.

Guide Specifications

General System Description

Overview of the split-system air conditioner unit's purpose and suitability.

Quality Assurance and Construction

Details on unit certifications, standards compliance, and construction quality.

Equipment and Cabinet Details

Description of factory-assembled components, unit cabinet materials, and fans.

Refrigeration and Operating Characteristics

Information on refrigeration components, capacity, and power consumption.

Electrical Requirements and Special Features

Nominal electrical characteristics, voltage limits, and available enhancements.