BLK BLACK
BLU BLUE
BRN BROWN
GRN GREEN
GRY GRY
ORG ORANGE
RED RED
WHT WHITE
YEL YELLOW
COLOR CODE
Caractéristique critique
Critical characteristic
CONNECTION DIAGRAM
123
456
789
123
345
6789
J3
J2J1
J4
FF I OC OL BRYG
FAN MOTOR
DAMPER MOTOR
120V, 60Hz
NEMA-15P
5-15 PLUG
(note 4)
MOTOR
CAPACITOR
BRN
BRN
BLU
RED
BLU
BLU
WHT
NC
GRY
ORG
BLU
YEL
BLK
WHT
-t
DEFROST TEMPERATURE
SENSOR
(COMMON)
(NO CONTACT)
(NC CONTACT)
BLK
GRN
RED
YEL
RED
BLK
YEL
WALL CONTROL
NOTE 1
OVERRIDE
OPTIONAL
Connect to G on Furnace/Fan coil
Connect to G on Thermostat
Connect to R on Furnace/Fan coil
MED
LO
NEUTRAL
FAN MOTOR
DAMPER MOTOR
HI
LO
K5
RELAY
K1
RELAY
K2
RELAY
K3
RELAY
MED
J1-4
J1-6
J1-9
J3-2
J3-1
J1-3
J1-1
J1-8
J1-2
120V, 60Hz RETURN
AIR HANDLER
FAN INTERLOCK
24 VAC
CLASS 2 CIRCUIT ONLY
LOGIC DIAGRAM
LINE VOLTAGE
CLASS 2 LOW VOLTAGE
AND FIELD WIRING
GAB CDEF
RED
321
HI
ORG
GRY
GRN
321
GRN
GRN
GRN
GRN
WAR NI NG
ELECTRICAL
SHOCK HAZARD
Disconnect power before servicing /
maintenance or eld wiring. Reinstall all
panels before operating. Failure to do so
can result in death or electrical shock.
AVERTISSEMENT
RISQUE DE CHOC ÉLECTRIQUE
Débranchez la source d'alimentation
électrique avant l'entretien, la
réparation ou le raccordement sur
place . Replacez tous les panneaux
avant d'utiliser. Le non-respect de ces
instructions peut causer un décès ou
un choc électrique
ADVERTENCIA
PELIGRO DE CHOQUE ELÉCTRICO
Desconecte el suministro de energía
antes de reparar, de mantener o de
cablear in situ. Vuelva a colocar todos
los paneles antes de hacer lo
funcionar. No seguir estas
instrucciones puede causar la muerte o
choque eléctrico.
NOTES
1- CONTROLS AVAILABLE SEE THE INSTRUCTION MANUAL
2- IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED MUST BE
REPLACED, USE THE SAME OR EQUIVALENT WIRE.
3- FACTORY SET WIRING FOR BLOWER SPEED IS HIGH AND
LOW SPEED. MEDIUM SPEED CAN BE SELECTED INSTEAD OF
LOW SPEED. DISCONNECT RED WIRE FROM MOTOR(S) RED
TAP AND CONNECT TO
MOTOR(S) BLUE TAP.
4- USE SPECIFIED UL LISTED /CSA CERTIFIED LINE FUSE .
FOR ALL UNITS: LITTELFUSE (225 003), 2AG FAST-ACTING FUSE,
224/225 SERIES, RATING: 3 A
F
Door interlock
switch
J1-3
120V, 60Hz LINE
F
BLK
Defrost cycles (minutes)
(Defrost / ventilation)
32
ELBAT REPMUJ
°
F5
°
F-17
°
F
JU1-A JU1-B JU1-C JU1-D JU1-E JU1-F JU1-G MODEL
-5
°
C-15
°
C-27
°
C
IN OUT OUT IN IN IN OUT ERVBBLHA1150 10/60 10/30 10/20
IN OUT OUT IN IN IN OUT ERVBBLHA1200 10/60 10/30 10/20
IN OUT OUT IN IN OUT OUT
Extended defrost all
mo d el s
10/30 10/20 10/15
GAB CDEF
FUNCTION TABLE RELAY
MODE K1 K2 K3 K5
Intermittent (20 min per hour) 0 0 0 1
Exchange Low 1 0 1 0
Exchange High 1 1 1 0
Circulation Low 1 0 1 1
Circulation High 1 1 1 1
11
1
1elcyC tsorfeD
1000FFO
0 = Relay coil is de-energized 1 = Relay coil is energized
A09191
Fig. 12 -- ERV Wiring Diagram