PRODUCT DATA INFORMATION
Current Compatible Communicating Products
Air Conditioning units -- 180B, 187B, 186B
Heat Pumps -- 286B, 289B, 285B
Gas Furnace -- 355AAV, 315AAV, 315JAV, 355CAV
Fan Coils -- FE
Small Packaged Products -- 577D, 707D, 607D, 677D
Physical Characteristics
Dimensions: See drawing
Appearance: Plastic, white color, textured
Electrical Characteristics/Communication
Input Volts/Amps 24VAC
Each device in the Evolution System has a four--pin
connector labeled ABCD. It is recommended that the
following color code be used when wiring each device:
A — Green = Data A
B — Yellow = Data B
C — White = 24VAC (Com)
D — Red = 24VAC (Hot)
Environmental Requirements:
Operating Temperature/Relative Humidity:
User interface and all sensors: 32_F to 104_F/0_Cto40_C,
95% rh non-- condensing
Storage Temperature/Relative Humidity:
User interface: -- 40_F to 134_F/--40_C to 56.7_C, 95% rh
non--condensing
Feature Specifications:
Temperature set point range: 40_Fto90_F/4.4_C to 32.2_C
Separate heat and cool setpoints
Programming days: 7 day
Programming periods:
2--Day, Sleep
4--Wake, Day, Eve, Sleep
Non--Programmable
Auto changeover (may be disabled)
Programmable fan (installer selectable)
Humidity Sensor Offsets
Auto Changeover Timer (installer adjustable)
Smart Recovery (in heating and cooling)
Hold function
Copy functions: Copy period, day and zone
Permanent memory
Humidity display and control
Temperature sensor offsets (indoor and outdoor)
TrueSenset Dirty Filter Detection
Wiring Requirements:
Power supply: Dedicated 24VAC, 40 va, 60 Hz, via indoor
equipment ABCD Connector. Isolated transformer, field
supplied.
Wiring material: Standard thermostat wire 18 to 24 gauge.
Equipment
DESCRIPTION PART NO.
Evolution Control (4--- Wire User Interface w/ multiple functionality) SYSTXBBUID01--- D
Evolution Network Interface Module (NIM) SYSTXBBNIM01*
* Required for ventilator control
Required for Hybrid Heat applications with non-- communicating heat pumps
Required for use with 2-- stage (non --communicating) AC or HP (598A / 698A)
Optional Accessories
DESCRIPTION PART NO.
Evolution Remote Room Sensor SYSTXBBRRS01*
Evolution Large Decorative Backplate SYSTXBBLBP01--- C
10 Pack Replacement --- Green Indoor Unit Plug (ABCD Connector) SYSTXGRPLG10
Evolution System Access Module (Remote Access Kit, Wired, CAT5) SYSTXBBRCT01
Evolution System Access Module (Remote Access Kit, Wireless WiFi) SYSTXBBRWF01
Outdoor Sensor TSTATXXSEN01--- B
* Not required, but may be used to remote sense indoor room temperature.
SYSTXBBUID01--D