FEATURES AND BENEFITS
S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
S 3 --6 ton units fit on existing Bryant small rooftop curb. This saves time and money on replacement jobs.
S Standardized c omponents and l ayout. Standardized components and controls make service and stocking pa rts easier.
S Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble --shooting easier.
S Field c onvertible airflow (3--6 tons). Being able to convert a unit from vertical ai rflow to horizontal makes it easy to
overcome job site complications.
S Easy--adjust, belt--drive motor a vailable. Bryant provides a factory solution for most points in the fan performance table.
There ’s no need for field--supplied drives or motors.
S Provisions for bottom or side c ondensate drain.
S Capable of thru--the--base or thru--the--curb electrical routing.
S Single--point electrical connection.
S Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust.
S Standardized c ontrols and control box layout. Standardized components and c ontrols make stocki ng parts and se rvice
easier.
S Clean, easy to use control box.
S Color--coded wiring.
S Large, laminated wiring and power drawings which are affixed to unit make troubleshooting easy.
S Single, central terminal board for test and wiring connections.
S Fast--access, handled, panels for easy access to the blower and blower motor, control box, and compressors.
S “No--strip” screw system guides scre ws into the panel and captures the m tightly without stripping the screw, the panel, or
the unit.
S Exclusive, newly --design i ndoor refrigerant header for easier maintenance and replacement.
S Mechanical cooling (115_F--25_F/46_C--4_C) on Direct Digit al Controller (DDC) (RTU--MP controller).
S Mechanical cooling (115_F--25_F/46_C--4_C) on Electro--Mechanical (E/M) models, with winter start kit.
S Bryant’s naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically,
manua lly drained. This saves labor and maintenance expense.
S 2” throw away filters on all units.
S Refrigerant filter --drier.
S High and low pressure switches. Added reliability with high pressure switch and low pressure switch.
the environmentally sound refrigerant
This product has been designed and manufactured to
meet Energy Star® criteria for energy efficiency.
However, proper refrigerant charge and proper air flow
are critical to achieve rated capacity and efficiency.
Installation of this product should follow all
manufacturer’s refrigerant charging and air flow
instructions. Failu re to con firm proper charge and
air flow may reduce energy efficiency and shorten
equipment li f e.
558J