8
Table 1 – Physical Data -- Unit 574D ----A
UNIT SIZE 24040 24060 30040 30060 36060 36090 42060 42090
NOMINAL CAPACITY (ton) 2 2 2 --- 1 / 2 2 --- 1 / 2 3 3 3 --- 1 / 2 3 --- 1 / 2
SHIPPING WEIGHT** lb.
SHIPPING WEIGHT** (kg)
311
141
311
141
316
143
316
143
326
148
326
148
420
191
420
191
COMPRESSORS
Quantity
Scroll
1
REFRIGERANT (R ---410A)
Quantity lb.
Quantity (kg)
4.8
2.2
4.8
2.2
6.2
2.8
6.2
2.8
6.4
2.9
6.4
2.9
6.1
2.7
6.1
2.7
REFRIGERANT METERING DEVICE TXV
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
1..21
10.2
1...21
10.2
1...21
11.9
1...21
11.9
1...21
15.4
1...21
15.4
1...21
13.6
1...21
13.6
OUTDOOR FAN
Nominal CFM
Diameter in.
Diameter (mm)
Motor Hp (Rpm)
2800
24
609.6
1/5 (810)
2800
24
609.6
1/5 (810)
3000
24
609.6
1/5 (810)
3000
24
609.6
1/5 (810)
3200
24
609.6
1/5 (810)
3200
24
609.6
1/5 (810)
3600
26
660.4
1/5 (810
3600
26
660.4
1/5 (810)
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
2...17
3.7
2...17
3.7
3...17
3.7
3...17
3.7
3...17
3.7
3...17
3.7
3...17
4.7
3...17
4.7
INDOOR BLOWER
Nominal Cooling Airflow (Cfm)
Size in.
Size (mm.)
Motor HP (RPM)
800
10x10
254x254
1/2 (1050)
800
10x10
254x254
1/2 (1050)
1000
10x10
254x254
1/2 (1050)
1000
10x10
254x254
1/2 (1050)
1200
11x10
279.4x254
3/4 (1000)
1200
11x10
279.4x254
3/4 (1000)
1400
11x10
279.4x254
3/4 (1075)
1400
11x10
279.4x254
3/4 (1075)
FURNACE SECTION*
Burner Orifice No. (Qty...Drill Size)
Natural Gas (Factory Installed)
Propane Gas
2...44
2...55
2...38
2...53
2...44
2...55
2...38
2...53
2...38
2...53
3...38
3...53
2...38
2...53
3...38
3...53
HIGH--PRESSURE SWITCH
(psig) Cut--out Reset (Auto)
650 +/-- 15
420 +/-- 25
LOSS--OF--CHARGE / LOW--PRESSURE
SWITCH (Liquid Line) (psig) cut--out Reset
(auto)
20 +/-- 5
45 +/-- 10
RETURN --- AIR FILTERS†}
Throwaway Size in.
(mm)
20x20x1
508x508x25
20x24x1
508x610x25
24x30x1
610x762x25
Table 1—Physical Data Con’t -- Unit 574D -- --A
UNIT SIZE 48090 48115 48130 60090 60115 60130
NOMINAL CAPACITY (ton) 4 4 4 5 5 5
SHIPPING WEIGHT** lb
SHIPPING WEIGHT** kg
428
194
428
194
428
194
450
204
450
204
450
204
COMPRESSORS
Quantity
Scroll
1
REFRIGERANT (R ---410A)
Quantity lb
Quantity (kg.)
6.4
2.9
6.4
2.9
6.4
2.9
10.0
4.5
10.0
4.5
10.0
4.5
REFRIGERANT METERING DEVICE TXV
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
1...21
15.5
1...21
15.5
1...21
15.5
2...21
15.5
2...21
15.5
2...21
15.5
OUTDOOR FAN
Nominal Cfm
Diameter in.
Diameter (mm)
Motor Hp (Rpm)
4000
26
660.4
1/5 (810)
4000
26
660.4
1/5 (810)
4000
26
660.4
1/5 (810)
3200
26
660.4
1/5 (810)
3200
26
660.4
1/5 (810)
3200
26
660.4
1/5 (810)
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
3...17
4.7
3...17
4.7
3...17
4.7
3...17
5.7
3...17
5.7
3...17
5.7
INDOOR BLOWER
Nominal Cooling Airflow (Cfm)
Size in.
Size (mm)
Motor HP (RPM)
1600 1600 1600 1750 1750
11x10
279.4x254
1.0 (1075)
11x10
279.4x254
1.0 (1075)
11x10
279.4x254
1.0 (1075)
11x10
279.4x254
1.0 (1040)
11x10
279.4x254
1.0 (1040)
1750
11x10
279.4x254
1.0 (1040)
FURNACE SECTION*
Burner Orifice No. (Qty...Drill Size)
Natural Gas (Factory Installed)
Propane Gas
3...38
3...53
3...33
3...51
3...31
3...49
3...38
3...53
3...33
3...51
3...31
3...49
HIGH--PRESSURE SWITCH
(psig) Cut--out Reset (Auto)
650 +/-- 15
420 +/-- 25
LOSS--OF--CHARGE / LOW--PRESSURE
SWITCH (Liquid Line) (psig) cut--out Reset
(auto)
20 +/-- 5
45 +/-- 10
RETURN--AIR FILTERS Throwaway†} in.
(mm)
24x36x1
610x914x25
*Based on altitude of 0 to 2000 ft (0---610 m) .
{ Requ ired filter sizes shown are based on the larger of the AHRI (Air Conditioning, Heating and Refrigeration Institute) rated cooling airflow or the heating
airflow velocity of 300 ft/minute for throwaway type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. W.C.
} If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.
** For 460 volt units, add 14 l bs (6.35 kg) to the shipping weight.
574D-- -- A