S Approximately 5 ft (1.5m) from floor.
S Close to or in a frequently used room, preferably on an inside partition-
ing wall.
S On a section of wall without pipes or duct work.
AC/HP Control should NOT be mounted:
S Close to a window, on an outside wall, or next to a door leading to the
outside.
S Exposed to direct light or heat from a lamp, sun, fireplace, or other tem -
perature- radiating objects which could cause a false reading.
S Close to or in direct airflow from supply registers and return- air regis-
ters.
S In areas with poor air circulation, such as behind a door or in an alcove.
Installer should determine whether control will be installed as single - piece or
two - piece. In single- piece configuration, as many as 14 wires may need to run to
wall mounting location for connection to the control. In two - piece configuration,
the Display Module and Equipment Control Module are connected by two wires.
Install AC/HP Control
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing AC/HP Control, turn off all power to equipment.
There may be more than 1 power disconnect.
!
WARNING