3
INSTALLATION CONSIDERATIONS
Power
This control is powered by 24VAC only. It requires 24VAC (Rh and/or Rc and C
terminals) of the low- voltage transformer to be connected to it for proper operation.
It will not operate without these 2 connections. Rh and Rc are connected via PCB
breakout jumper. See Fig. 1. For applications using two 24VAC transformers, one in
the indoor unit and one in the outdoor unit, connect the common from each to the C
terminal. Connect R from the indoor unit to the Rh terminal. Connect R from the
outdoor unit to the Rc terminal. Then, break jumper on the circuit board. The W
signal is taken from the Rh power and the G signal is taken from the Rc power. If
thermostat has been installed in a two- transformer application that is later changed
to a single- transformer installation, installer must install a field supplied jumper
between Rc and Rh. Depending on the installation, up to 14 wires may be required.
Installation as two- piece unit is recommended. Only 2 wires are required for
connection between Display Module and Equipment Control Module. These two
wires (V+ and Vg) do not provide ordinary 24VAC. They carry a combination of
power and communications data that is unique to these products.

Other manuals for Bryant T6-NHP01-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant T6-NHP01-A and is the answer not in the manual?

Bryant T6-NHP01-A Specifications

General IconGeneral
BrandBryant
ModelT6-NHP01-A
CategoryThermostat
LanguageEnglish

Related product manuals