EasyManuals Logo

Bryant T6?PRH?A User Manual

Bryant T6?PRH?A
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
78
Equipment Control Module
Furnace Air Conditioner
Heat Stage 2 O/B W2 W2
Heat Stage 1 W/W1
W/W1
Cool Stage 1 Y1 / W2 Y1
Cool Stage 2 Y/Y2 Y/Y2 Y/Y2
Fan G G
24VAC Hot Heating Rh R R
24VAC Hot Cooling Rc
Dry Contact 1 D1
Dry Contact 2 D2 DHUM
24VAC Common C COM C
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com SRTN
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
Y1
* Indicates connection may not be required/available.
A09123
Fig. 32 Variable Speed, Step Modulating, MultiStage and SingleStage
Furnace with TwoStage Air Conditioner