21
Response time < 100s
Capacitance
RANGE Accuracy
1)
60.00nF, 600.0nF 0.8% + 3d
6.000F
1.0% + 3d
60.00F
2.0% + 3d
600.0F
2)
3.5% + 5d
6.000mF
2)
5.0% + 5d
25.00mF
2)
6.5% + 5d
1)
Accuracies with film capacitor or better
2)
In manual-ranging mode, measurements
not specified below 50.0F, 0.54mF and
5.4mF for 600.0F, 6.000mF and 25.00mF
ranges respectively
AC & AC+DC Current
RANGE Accuracy
Burden voltage
Model
811
812
829
Model
811XEX
812XEX
525
50Hz ~ 60Hz
600.0A
,
6000A
0.6%+3d
0.08mV/A 0.08mV/A
60.00mA
1.5mV/mA 2.1mV/mA
600.0mA 1.0%+3d
6.000A,
10.00A
1)
0.8%+6d 0.04V/A 0.02V/A
40Hz ~ 1kHz
600.0A
,
6000A
0.8%+4d
0.08mV/A 0.08mV/A
60.00mA
1.5mV/mA 2.1mV/mA
600.0mA 1.0%+4d
6.000A,
10.00A
1)
0.8%+6d 0.04V/A 0.02V/A
1)
10A continuous, >10A to 15A (to 20A for
TBM525, TBM811XEX & TBM812XEX) for
30 second max with 5 minutes cool down
interval
DC Current
RANGE Accuracy
Burden voltage
Model
811
812
829
Model
811XEX
812XEX
525
600.0A
,
6000A
0.2%+4d
0.08mV/
A
0.08mV/
A
60.00mA,
600.0mA
1.5mV/mA 2.1mV/mA
6.000A,
10.00A
1)
0.04V/A 0.02V/A
1)
10A continuous, >10A to 15A (to 20A for
TBM525, TBM811XEX & TBM812XEX) for
30 second max with 5 minutes cool down
interval
Line Level Frequency (~Hz)
Function Range Frequency Sensitivity
(Sine RMS)
AC 60.00mV 15.00 ~
50.00kHz
40mV
AC 600.0mV 60mV
AC 9.999V
15.00 ~
10.00kHz
2.5V
AC 99.99V 25V
AC 999.9V 100V
AC 600.0A
15.00 ~
3.000kHz
200A
AC 6000A 600A
AC 60.00mA 40mA
AC 600.0mA 60mA
AC 6.000A 4A
AC 10.00A 6A
Accuracy: 0.04%+4d