Front Panel Menu Navigation
Error Codes
Your BDP-3 may display an error code in certain power line disruption events or if there is a problem booting.
The following is a brief description of each.
ERROR 03
Microprocessor does not detect voltage on main Analog Power Supply perhaps due to blown fuse faulty power
supply wiring harness. BEFORE INVESTIGATING POWER SUPPLY ISSUES, DISCONNECT MAINS POWER FROM UNIT!
ERROR 04
AC Line voltage has momentarily sagged below threshold suicient to maintain power to main board. Minimum
line voltage specs for 120V and 240V units are approximately 100V and 190V respectively. Simply rebooting the unit
will clear this error presuming the faulty AC mains condition no longer exists.
ERROR 05
AC Line voltage has momentarily exceeded the high threshold the power supply can tolerate. Maximum line
voltage specs for 120V and 240V units are approximately 128V and 254V respectively. Simply rebooting the unit will
clear this error presuming the faulty AC mains condition no longer exists.
ERROR 09
This message occurs if the microprocessor doesn’t receive a response from the main board running the main
operating system. This can happen if the rmware on the built-in ash card becomes corrupted, if the BDP is
mistakenly trying to boot from an attached drive, or in rare instances, if the serial cable connecting the main board
to the power supply is loose.
If the error occurs aer a power failure, failed rmware upgrade, or other major system disruption, contact Bryston
for information on how to re-ash your BDP-3’s internal CF card. If the error occurs upon the rst boot sequence
aer connecting a new USB drive, try removing the drive and restarting again. If it boots with no problem, contact
Bryston for instructions on resolving the problem with your drive.
If neither of these work, contact Bryston for instructions on how to verify the integrity of the internal serial cable.
Pressing the up arrow
and le arrow in quick
succession brings up a
menu that allows for the
following adjustments:
Display Brightness: 1-4
Display Timeout: 10
seconds to never.
IR Address: 1-7 (for
controlling multiple
devices)
Device ID: 6-BR2 Control,
9-future IR remote control