ISOCYANURIC ACID (mg/l)
--
<75
OZONE (GLASS) (mg/l)
--
0
OZONE (before)
0.4
--
TURBIDITY (NTU)
--
<1
OXIDES (mg/l)
--
<3
NITRATES (mg/l)
--
<20
AMMONIA (mg/l)
--
<0.3
IRON (mg/l)
--
<0.3
COPPER (mg/l)
--
<1.5
ALKALINITY (mg/l)
100
160
CONDUCTIVITY (us/cm)
--
<1700
TDS (mg/l)
--
<1000
HARDNESS (mg/l)
150
250
3- INSTALLATION OF THE EQUIPMENT
3.1- General considerations:
Place the chlorine cell in a vertical position with electrical connections facing
upwards. If this is not possible, it can be assembled in a horizontal position,
ensuring that the small auxiliary electrode faces upwards.
Place the chlorination cell in the highest position possible of the purification
circuit and always after the filter.
If possible, it is recommended to install the cell with a by-pass system with
its corresponding shut-off valves. This is to facilitate maintenance of the cell.