Functions and parameters
Parameters
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT Repair Manual RRE140/160/180/200/250 4 – 69
4.13.2 Displaying/changing parameters
See the "Settings menu (SET)" for instructions on how to display and
change the parameter settings.
4.13.3 Parameters
Operator parameters, overview
No. Min. Max. Increments Default Unit Description
1 1 6 1 3 Steering, speed-depend-
ent deflection
2 1 10 1 10 10 % Maximum speed, drive
wheel direction
3 1 10 1 8 10 % Maximum speed, fork
direction
4 3 10 1 8 10 % Acceleration
5 3 10 1 8 10 % Automatic brake
6 500 10 000 100 1000 mm Height above free lift
once the Ergo cabin
starts tilting.
Operator Parameter number
1 1–10
2 11–20
3 21–30
4 31–40
5 41–50
6 51–60
7 61–70
8 71–80
9 81–90
10 91–100