Electrical system 5000
Parameter settings
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT Repair Manual RRE140/160/180/200/250 13 – 11
13.3 Parameter settings
13.3.1 Configuration menu
Calendar/hour counter menu
The calendar and hour counter menu display hour counter and calen-
dar data. If a service key is connected, the date and time can be
changed.
To set the current date and time, use the arrow keys to select the value
to be changed (hours, minutes, month and day), as well as the plus/
minus buttons to make the changes. The new settings are stored in the
MCU by pressing the green button (I).
The hour counter menu displays the values for hour counters A, B, C, D
and S:
If the service hour counter is deactivated, service parameter 101, the
service time is not displayed.
Parameter menu (PAR)
To be able to change the parameters, a service key must be connected.
If the key is not connected, the parameters can only be read.
Each parameter can be reached by entering the parameter number in
the box marked "Par". The parameter value can be enterd using the
numerical keypad, or the plus/minus buttons.
The plus button increases the number by one (1) and the minus button
reduces it by one (1).
The value of the parameter is displayed in the box under "Par". The val-
ue is changed by using the arrow key to select this box and then enter-
ing the value with the keypad or the plus/minus buttons. The value is
saved by pressing the green button (I).
The parameter's default value can be selected by selecting the factory
icon and pressing the green button (I).
A Total time
B Active time
C Driving/Operating time
D Hydraulics time
S Time until service