13 – 16 Repair Manual RRE140/160/180/200/250 © BT
Electrical system 5000
Calibrations
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
13.4.2 Joystick calibration
1. Use the arrow keys to select the top left box. Change the value with
+/- keys to correspond to the joystick to be calibrated.
2. Move the selection down, with the arrow keys, to the bottom left
box.
3. Move the joystick to its maximum position and press the green key.
The CID detects the value and stores it as “Max”.
4. Release the joystick to its neutral position and press the green key.
5. Move the joystick to its minimum position and press the green key.
Repeat steps 1 to 5 for other joysticks that have to be calibrated.
13.4.3 Weight calibration
The weight mode is used to calibrate the fork load indicator.
Calibrating the weight indicator
1. Lower the unladen forks to the floor.
2. Lift them at full speed to about 1 metre above the ground.
3. Wait for about 1 minute.
4. Using the arrow keys, select the box on the right .
5. Read off the weight on the CID screen (in the middle at the top).
Use the plus/minus buttons to adjust the read value to 0
5 kg).
6. Take a load of known weight (over 500 kg) on the forks.
7. Change the value "1000" in the bottom left-hand box to the known
weight of the load.
8. Lower the forks to the floor and lift them at full speed to 1 metre
above the ground.
9. Wait for about 1 minute.
10. Select the box on the bottom right.
11. Read off the weight on the CID screen. Use the plus/minus buttons
to adjust the read value to the known weight of the load
5 kg).
Repeat steps 1 to 8 as necessary.