EasyManua.ls Logo

Bubble CORNER - Connection to Flues; Ventilation

Bubble CORNER
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
plugged with a suitable bolt.
The flue draft readings should be taken when the appliance is at minimum firing rate and
maximum firing rate.
When taking readings get the appliance up to the required temperature and then make sure
that the primary air is closed and the air wash is open.
The chimney vacuum should be within the figures stated in TABLE1.
See fig7 for general guidance on flue heights and terminal positions.
If in doubt seek expert advice.
C
C
O
O
N
N
N
N
E
E
C
C
T
T
I
I
O
O
N
N
T
T
O
O
F
F
L
L
U
U
E
E
S
S
.
.
Stoves can be connected to flues using single wall flue pipe of suitable diameter, see
TABLE 1 for relevant flue pipe diameters.
All connections must be correctly sealed to prevent any smoke or fume leakage.
If in doubt seek expert advice.
V
V
E
E
N
N
T
T
I
I
L
L
A
A
T
T
I
I
O
O
N
N
.
.
The provision of ventilation for this appliance is 550mm sq for each kilowatt of stove
output.
STOVES
OUTPUT TO WATER IN
KW
OUTPUT TO SPACE IN
KW
TOTAL OUTPUT IN
KW
VENTILATION IN CM
SQ
CORNER MF 1-4KW 4KW 22
WET VERSION 1-3KW 1-2KW 5KW 27.5
3B WOOD 1-3KW 3kW 16.6
BOILER VERSION 1-2KW 1-3KW 3kW 16.5
B4 MF 1-5KW 5KW 27.5
WET VERSION 1-3KW 1-2KW 5KW 27.5
B7 2-7KW 7KW 38.5
SMALL BOILER 1-3KW 1-4KW 7KW 38.5
LARGE BOILER 2-8KW 1-3KW 11KW 60.5
OVEN STOVES
CORNER MF POD 1-4KW 4KW 22
WET VERSION 1-3KW 1-2KW 5KW 27.5
B4 MF POD 1-5KW 5KW 27.5
WET VERSION 1-3KW 1-2KW 5KW 27.5
B7POD 2-8KW 7KW 38.5
SMALL BOILER 1-3KW 1-4KW 7KW 38.5
LARGE BOILER 2-8KW 1-3KW 11KW 60.5
MINI COOKER 1-3KW 3kW 3KW 16.6
If the appliance is fitted into a location which has an extractor fan fitted, additional
ventilation will be required to compensate for the effects of the extractor unit.
Where air for ventilation is taken from another space and not directly from outside air,
the ventilation allowance needs to be doubled.
Make sure that the appliance is fully and correctly assembled, and that the baffle plate is
correctly fitted.