EasyManua.ls Logo

Buderus 500 Series User Manual

Buderus 500 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Please read thoroughly before operating the unit
7215 3400 - 02/2006 GB (EN) For the user
Users manual
Gas wall hung Boiler condensing
Buderus 500 - 24/S
W
Question and Answer IconNeed help?

Do you have a question about the Buderus 500 Series and is the answer not in the manual?

Buderus 500 Series Specifications

General IconGeneral
TypeCondensing Boiler
Fuel TypeNatural Gas or Propane
DimensionsVaries by model
Modulation Ratio5:1
Ignition TypeElectronic
Operating Pressure30 psi (typical)

Summary

Introduction

Important General Instructions for Use

General safety and usage guidelines for the boiler, emphasizing intended purpose and regulations.

Preface

Safety Precautions

Gas Leak Emergency Procedures

Emergency actions for gas leaks, including no flames, avoiding sparks, shutting off gas, and evacuation.

Incident Response Protocol

Actions for other incidents, involving shutting off power and seeking professional help from a CORGI engineer.

Installation Area and Boiler Room

Airflow Requirements and Warnings

Warning against reducing or closing air intake and outlet openings for the boiler.

Flammable Materials and Contamination Prevention

Prohibition of flammable materials and notes on preventing contamination and ensuring proper ventilation.

Working in the Heating System

Authorized Personnel and Responsibilities

Mandate that only CORGI registered engineers perform installation, commissioning, servicing, and repairs.

System Design and Service Recommendations

Boiler designed for central heating/hot water; recommendation for service contracts with specialists.

System Functions and Maintenance

Functions and Operating Instructions

Requirement for installers to familiarize users with system functions and provide documentation.

Maintenance Interval Requirements

Details annual inspection and maintenance for warranty and optimal functioning under normal conditions.

Conversion to LPG

Abbreviations

Permanent Clearances

Installation Clearance Specifications

Specification of required permanent clearances around the boiler for installation.

Service Clearances and Wall Frames

Clarification on permanent clearances with wall spacing frames and the need for sufficient service clearances.

DBA Control Unit

DBA Overview and Mains Switch

Introduction to the DBA control unit and explanation of the mains switch for power control.

Reset Button Functionality

Explanation of the reset button's use for restarting the boiler during specific fault conditions.

Service Button and Display Usage

Warning against using the service button and description of the display for settings and fault codes.

Menu Button and Adjustment Keys Operation

Instructions for using the menu button and adjustment keys (C/D) for temperature settings and operation modes.

Initial Start-up Procedures

Preparation and System Pressure Check

Steps to prepare the boiler for operation, including checking external controls and system water pressure.

Topping Up the Heating System

Procedure for filling the heating system with mains water while the boiler is off.

Filling Loop Connection and Radiator Venting

Steps for connecting and using the filling loop, and venting radiators from air.

Post-Venting Pressure Check and Water Loss Handling

Instructions to re-check pressure after venting and actions for frequent water losses.

Setting Domestic Hot Water and Summer Operation

How to set DHW temperature and configure summer operation mode using the control unit.

Setting Central Heating Flow Temperature

How to adjust the central heating flow temperature using the control unit's keys.

Operational and Fault Code Interpretation

Guide on viewing operational states and fault codes, and their meanings and rectifications.

Taking the System Out of Service

System Shutdown and Gas Valve Closure

Steps to take the system out of service, including switching off the mains power and closing the gas valve.

Frost Protection and System Draining

Draining Procedure for Frost Conditions

Procedure for draining the system for extended shutdowns or frost conditions, including valve operations.