EasyManua.ls Logo

Bunn C Series - Control Thermostat; ON;OFF Switch; Start Switch (Brew)

Bunn C Series
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 5
TROUBLESHOOTING (cont.)
Brew cycle will not start (cont.)
Water is not hot
PROBABLE CAUSE
REMEDY
3. ON/OFF Switch
4. Start Switch
5. Timer
6. Solenoid Valve
7. Water strainer/flow control
(.222 GPM) Early models
1. Tank Heater Switch
2. (A) Limit Thermostat
(B) Thermal Cut-Off (Brewers
with Faucet)
CAUTION - Do not eliminate
or bypass limit thermostat or
thermal cut-off. Use only BOM
replacement parts.
3. Control Thermostat
4. Tank Heater
Refer to Service - ON/OFF
Switch for testing.
Refer to Service - Start Switch
for testing procedures.
Refer to Service - Timer for test-
ing procedures.
Refer to Service - Solenoid Valve
for testing procedures.
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/flow
control and check for obstruc-
tions. Clear or replace.
Refer to Service - Tank Heater
Switch for testing procedures.
Refer to Service - Limit Ther-
mostat for testing procedures.
Thermal Cut-Off for testing
procedures.
Refer to Service - Control Ther-
mostat for testing procedures.
Refer to Service - Tank Heater
for testing procedures.
PROBLEM
41711.1 052009