EasyManua.ls Logo

Bunn DUAL - Advanced Troubleshooting Scenarios; Brew Cycle Start Issues (Continued); Automatic Refill Malfunction

Bunn DUAL
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 9
TROUBLESHOOTING (cont.)
Problem
Brew cycle will not start (cont.)
Automatic refill will not operate
Remedy
Refer to
Service
- ON/OFF switch for
testing procedures. See page 32
Refer to
Service -
Start switch for
testing procedures. See page 37
Refer to
Service -
Timer for testing
procedures. See page 39 or 42
Refer to
Service -
Dispense valve for
testing procedures. See page 22
Refer to
Service
- Control assembly
for testing procedures. See pages
23 thru 28
Check plumbing and shut-off valves.
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.
Refer to
Service
- Solenoid valve for
testing procedures. See page 36
Refer to
Service
- Limit thermostat
for testing procedures. See page 31
Refer to
Service -
Overflow protec-
tion switch for testing procedures.
See page 33
Refer to
Service
- Level control board
for testing procedures. See page 29
Refer to
Service
- Electronic con-
trols for testing procedures. See page
23 thru 28
Probable Cause
3. ON/OFF switch
4. Start switch
5. Timer
6. Dispense Valve
7. Control Assembly (Electronic)
1. No water
2. Water strainer/flow control
(.750 GPM)
3. Solenoid Valve
4. Limit thermostat (Electro/
mechanical and Electronic)
5. Overflow protection switch
6. (A) Level control board & level
probe. (Electro/mechanical con-
trolled)
(B) Electronic controls
27040 011904