PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
MASTER TEMP
This function allows the operator to adjust the brew
water temperature in the tank. This also sets the hot
water faucet dispense temperature.
Procedure for setting the Master Temp
Range: 185° to 207° F (85°-97° C)
1. Press and hold the right hidden button until the dis-
play reads SET LANGUAGE. Press the right hidden
button until the display reads MASTER TEMP.
2. Using (-) and (+), adjust the brew and faucet tem-
perature.
3. When fi nished, press and release DONE to save
the new setting and to advance to the next function
screen, READY DEGREE. Press and release the
ON/OFF pad to exit programming and return to the
MAIN SCREEN.
BREW
A
BREW
B
BREW
C
MASTER TEMP: 205°
(-) DONE (+)
READY DEGREE XXX
(-) DONE (+)
P2870
36748 101505