SE56
p. 1/7
www.burkert.com
Transmitter for electromagnetic-
inductive flow sensor fittings
The electronics Type SE56 (blind in compact ver-
sion or with display in compact or remote version) con-
nected to the magnetic flow sensor fitting Type
S051, S054, S055 or S056 is designed for
applications with liquids with a minimum con-
ductivity of 5
μS/cm.
The device can be parameterize either with 3
keypads (version with display) or by computer via a
serial interface.
As standard, the equipment is supplied with
one or two transistor outputs and one digital
input. As options, other features are available:
such as high frequency output, current output,
PROFIBUS DP, HART.
Technical data - Electronics SE56 standard with display
Compatibility
S051, S054, S055, S056 sensor fitting
(see separate data
sheet 8051, 8054/8055, 8056)
Housing materials Die casting aluminium or
stainless steel 304 electro-polish
Display
Graphic display 8 lines x 16 Characters, 128 x 64 pixels
with back light
Keyboard 3 membrane keys
Electrical connection 6 cable glands PG 11
Medium temperature, please see separate data sheets of the complete magflowmeter 8051, 8054/8055, 8056
Environment
Ambient temperature
Operating and storage - 20 + 60 °C (- 4 … + 140 °F)
Relative humidity
85 %, without condensation
Height above sea level - 200 + 6000 m
Standards, directives and certifications
Protection
Class I, IP67, category of installation II
Standards and directives
The applied standards, which verify conformity with the EU
Directives, can be found on the EU Type Examination Certifi-
cate and/or the EU Declaration of conformity
(if applicable)
Type SE56 must be combined with...
Must be equipped with sensor fitting S051, S054,
S055 or S056
Continuous measurement or batch control
High accuracy
PROFIBUS DP, HART available
SE56 standard
with display,
Housing in
stainless steel
SE56 blind
SE56 basic
Type S056
Magnetic sensor fitting
- Hygienic
Type S051
Magnetic sensor fitting
- for low flow
Type S054
Magnetic sensor fitting
- Wafer
Type S055
Magnetic sensor fitting
- Flange
Downloaded from Arrow.com.

Other manuals for Burkert SE56

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Burkert SE56 and is the answer not in the manual?

Burkert SE56 Specifications

General IconGeneral
BrandBurkert
ModelSE56
CategoryTransmitter
LanguageEnglish

Related product manuals