TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
9. OPERATION OF BOILER
-User`s training for operaon and
maintenance of boiler is performed by
an authorized installer.
Failuretoobservetheinstallaon
and operang requirements
described in the manual and
the service booklet voids the
warranty.
Protecveglovesmustbeused
9.1. Operationofboiler Pell Easy
Ignion.
After starting the boiler up from the control
panel, the main pellet auger conveys
certain amount of fuel in Combustion
chamber. This specic amount of pellets
is set by the installer and depends on the
fuel characteriscs. This specific amount
of pellets is being ignited using hot air.
Burning.
The burning process takes place in the
combustion chamber of the boiler, as the
fuel portions are dosed (measured) at
regular intervals by the integrated auger.
This achieves optimum combustion.
The boiler performance is controlled
and operated by a temperature sensor
that measures the temperature of the
water jacket (mantle) and a temperature
sensor that measures the temperature
of the exhaust gases. Ignition and stop
are controlled by the exhaust gas sensor,
which gives information to the control
unit. The power is determined by the
adjusted maximum temperature in the
boiler, as shortly before reaching it, it
starts modulating.
Selfcleaningsystem.
The boiler has a self-cleaning feature that
allows self-cleaning of the combustion
chamber. At regular intervals, the fan
starts on maximum power to clear the
residual ash in the combustion chamber.
Thus ensuring a long and effective
combustion process.
8. FILLING THE HEATING INSTALLATION
Table 6
Problem Prevenon
Possible installaon damage due
to strains in the material caused by
temperature dierences
Fill the heang installaon only in cold condions
(inlet temperature must not exceed 40°C).
Danger of installaon damage due
to accumulaon of deposits
Condensate formaon and tar
deposits may shorten boilers
operaonal life.
- Do not operate the heang boiler for a long period
of me in paral load mode
- The temperature at the boiler inlet must not be
less than 65°C, boiler water temperature must be
between 80°C and 85°C.
- Use the boiler for a short period to heat warm
water in the summer.
9.ЕКСПЛОАТАЦИЯНАКОТЕЛА