5
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Table 1.
Electricity consumpon of the boiler
Maximum electrical input 360 W
Electrical input at nominal heat
output
70 W
Electrical input at minimum
heat output
45 W
1.2.2.Instruconstoinstallaonuser
$
DANGER of intoxicaon or
explosion
Toxic gases may be discharged
when burning waste, plascs,
liquids.
- Use only the fuels indicated in
this manual.
- In case of danger of explosion,
ignion or discharge of exhaust
gases in the room, stop the pellet
burner from operaon.
Customer must undergo boiler
operaon/maintenance training
by authorized installer/service
shop.
CAUTION! Danger of injury
/ damage of system due to
incompetentoperaon.
- The boiler must be serviced only
by persons familiar with the
operaon manual.
- As user, you are only allowed to
start the boiler up, adjust the
temperature of the boiler, shut
the boiler down and clean it.
- Unaended children must not be
allowed access to premises with
running boiler inside.
Safetyrulesforuseroperaon:
- Operate the boiler on recommended fuel
only, and to that end you must regularly
inspect the boiler room.
- Do not use ammable liquids for ignion
or increase of burner output.
- Clean the boiler surface using non-
ammable agents only.
- Do not place ammable objects onto the
burner housing and heang boiler cabinet
or in their proximity. (see diagram 1 for
the minimum clearances)
- Do not store ammable materials in the
boiler room.
- It is mandatory to strictly observe
instrucons for connecng the burner
to power network as well as to all
peripherals.
- Structural changes of the boiler by user
can cause damage to equipment or injury.
- Do not allow contact transmission of
electrical wire or touch any part of the
boiler, where the surface temperature can
exceed 70 °C.
- This manual should be kept throughout
CAUTION!Hotsurface!
Risk of burns if you touch the
runningsystem.Burnerhousing,
bodyandangearehotsurfaces
duringburneroperaon.
It is strictly prohibited to open
boiler inspecon doors with the
burner running.
The hopper hatch cover is not
allowed to remain open for
longer periods of me.
Also, exercise cauon when
touching the observaon port for
monitoring the burning process.
It may be hot.
It is mandatory to assure a
backup power generator of
correspondingrated power!(see
table1)