Setup and function
Product manual 2CKA001473B8289
9
4 Setup and function
4.1 Functions
The temperature controller is used to control the temperature in closed rooms.
4.2 Features of function and equipment
Article no. Features / Function
1094...
Opens when the set temperature is reached.
With separate connection for time-controlled reduction of night-time temperature (4
K).
Servo valves of "closed when de-energized" design are required for the controller.
1095...
Opens when the set temperature is reached.
With normally open contact (not applicable for 1095...).
With separate connection for time-controlled reduction of night-time temperature (4
K).
With installed sliding switch and control lamp for night-time temperature reduction (4
K).
Servo valves of "closed when de-energized" design are required for the controller.
...UF
With normally closed contact
With remote sensor (external temperature sensor for mounting in the floor) and
thermal feedback.
For electric floor heating.
Opening of the relay contact, when the set temperature is reached.
1096...
Opens when the set temperature is reached.
With separate connection for time-controlled reduction of night-time temperature (4
K).
With installed sliding switch and control lamp for night-time temperature reduction (4
K).
Servo valves of "closed when de-energized" design are required for the controller.
1097...
With switchover contact (heating / cooling).
Servo valves of "closed when de-energized" design are required for the controller.
...UTA
With display of actual temperature
Temperature display in 0.5°C steps.
Display accuracy: ±0.5°C for load currents of 2 A.
Display accuracy: ±1.5°C for load currents of >2 A.
Automatic controller calibration.