7 | Commissioning
18 | 40 Instruction Manual FOSSA FO 0015 A - FO 0035 B_EN_en
7 Commissioning
WARNING
FO 0035 B operates at 100 hPa (mbar) in continuous operation.
Risk of damage to the machine!
ATEX Risk of explosion and injuries!
Make sure to comply with the maximum continuous suction pressure, see Technical Data [35].
CAUTION
During operation the surface of the machine may reach temperatures of more than 70°C.
Risk of burns!
Avoid contact with the machine during and directly after operation.
NOTE
A small amount of tip seal dust may collect in the exhaust duct of the machine. The dust may
be blown out when the machine is vented.
Make sure that the Installation Conditions [11] are met.
Start the machine.
Make sure that the maximum permissible number of starts does not exceed 6 starts per hour.
Those starts should be spread within the hour.
NOTE
For the single phase version, take into account a delay of 5 seconds between power-up and
the machine start up.
Make sure that the operating conditions comply with the Technical Data [35].
As soon as the machine is operated under normal operating conditions:
Measure the motor current and record it as reference for future maintenance and trouble-
shooting work.
7.1 Conveying Condensable Vapors
START
Close the isolation valve* and open the gas ballast valve** (GB)
Warm up the machine
Wait 30 minutes
Open the isolation valve* and perform the process
Close the isolation valve*
Wait 30 minutes
Close the gas ballast valve** (GB)